| Model Number |
1103 |
| Medical Device Problem Codes |
Use of Device Problem (1670); Power Problem (3010); Pumping Problem (3016)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
11/05/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Investigation of this event is pending and a supplemental report will be sent upon its completion.Additional products: d1: heartware ventricular assist system controller 2.0 d4: model #: 1420 / catalog #: 1420 / expiration date: 30-nov-2024 / serial #: (b)(6) d9: no h3: no h4: mfg date: 13-nov-2023 h5: no h6: the codes present in section h6 correspond to components/products that comprise the reported event.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
It was reported that the ventricular assist device (vad) exhibited a low flow alarm and the controller had an unexpected loss of power with an associated vad start event.The vad and controller remain in use.No patient complications have been reported as a result of this event.
|
| |
|
Additional Manufacturer Narrative
|
|
A supplemental report is being submitted for device evaluation.Product event summary: the ventricular assist device (vad) (b)(6) and the controller ((b)(6)) were not returned for evaluation.A review of the manufacturing documentation was not performed as the reported event and analysis are not related to a manufacturing or servicing issue.Log file analysis revealed intermittent decreases in power consumption and estimated flows throughout the analyzed period and one (1) low flow alarm logged on 05/nov/2025 at 16:30:17.Log file analysis revealed a controller power-up event, with an associated motor start event, logged on 07/nov/2025 at 10:09:40, indicating a loss of power to the controller.The data point recorded prior to the loss of power revealed that (b)(6) was connected to power port one (1) with 27% relative state of charge (rsoc) and (b)(6) was connected to power port two (2) with 78% rsoc.The data point recorded after the loss of power revealed that (b)(6) was connected to power port one (1) and (b)(6) was connected to power port two (2).No anomalies were recorded leading up to the loss of power.The controller was without power for eight (8) seconds.As a result, the reported loss of power event and low flow event were confirmed.Based on the available information, the device may have caused or contributed to the reported low flow event.Based on the risk documentation, possible causes of the reported low flow event may be attributed to multiple factors including but not limited to thrombus at the inflow cannula/outflow graft, constriction at the outflow graft, poor vad filling, and/or inappropriate pump rotational speed.The most likely root cause of the controller loss of power event can be attributed to the reported double disconnection of both power sources, as described in the event details.Capa pr00551638 investigated controller losses of power.Even though this capa is now closed, (b)(6) falls in scope of this capa.Additional products: d1: controller d4: serial#: (b)(6) h3: yes h6: the codes present in section h6 correspond to components/products that comprise the reported event.Investigation of this event is completed and the file will be closed.If new information is received, the file will be re-opened and a supplemental will be submitted.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Additional Manufacturer Narrative
|
|
A supplemental report is being submitted for additional information.Updated fields: b5.Desc evt problem h6.Device codes investigation of this event is pending and a supplemental report will be sent upon its completion.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
It was further reported that the loss of power occurred due to a double power disconnect.The patient was educated on proper power source changes.The controller remains in use.
|
| |
|