• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARROW INTERNATIONAL LLC ARROW CVC SET: 3-LUMEN 7 FR X 20 CM; CATHETER PERCUTANEOUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL LLC ARROW CVC SET: 3-LUMEN 7 FR X 20 CM; CATHETER PERCUTANEOUS Back to Search Results
Catalog Number CV-15703
Medical Device Problem Codes Difficult to Remove (1528); Stretched (1601)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 07/07/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
It was reported that "during the cvc placement procedure, the attending physician, attempting to remove the guidewire to introduce the cvc, experienced difficulty removing it because it stretched like chewing gum and became soft and tortuous.Two more attempts were made, but the same failure was detected.A total of three cvc devices were found to have failures." there was no medical intervention required.The patient was transferred to a different hospital.Associated mdr numbers include: 9680794-2025-00950, and 9680794-2025-00942.
 
Event or Problem Description
It was reported that "during the cvc placement procedure, the attending physician, attempting to remove the guidewire to introduce the cvc, experienced difficulty removing it because it stretched like chewing gum and became soft and tortuous.Two more attempts were made, but the same failure was detected.A total of three cvc devices were found to have failures." there was no medical intervention required.The patient was transferred to a different hospital.Associated mdr numbers include: 9680794-2025-00951, 9680794-2025-00950, and 9680794-2025-00942.
 
Additional Manufacturer Narrative
Qn# (b)(4).The actual device was not returned; however, the customer provided one photo and two videos for analysis.The complaint of an unraveled guide wire was able to be confirmed by the photo and videos.The videos/image show a used guidewire with evidence of unraveling, however, a complete visual inspection to determine the cause of the damage could not be performed as no sample was returned for analysis.A device history record review was performed, and no relevant findings were identified.The ifu provided with the kit informs the user, "do not use excessive force when introducing guidewire or tissue dilator as this can lead to vessel perforation, bleeding, or component damage".The ifu also states, "do not apply excessive force in placing or removing catheter or guidewire.Excessive force can cause component damage or breakage.If damage is suspected or withdrawal cannot be easily accomplished, radiographic visualization should be obtained and further consultation requested".The customer report of an unraveled guide wire was confirmed by visual inspection of the customer supplied photo and videos.The videos/image show a used guidewire with evidence of unraveling.A device history record review was performed, and no relevant findings were identified.Arrow guide wires of this size are designed and manufactured to withstand a tensile force of 2.75 pounds force.This internal specification is higher than the bs en iso 11070:2014 standard of 2.2 pounds force for this size wire.The selected insertion site and patient anatomy may present a tortuous path that could contribute to the possibility of guide wire kinking.Guide wire breakage may occur if a force greater than the design specification is applied during removal.Based on these circumstances, unintentional use error likely contributed to this event; however, the probable cause of guide wire and catheter resistance could not be determined based upon the information provided and without the device being returned for evaluation.Teleflex will continue to monitor and trend for reports of this nature.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARROW CVC SET: 3-LUMEN 7 FR X 20 CM
Common Device Name
CATHETER PERCUTANEOUS
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL DE MEXICO S.A. DE C.V.
ave. washington 3701
colonia panamericana, chihuahua
chihuahua 31200
MX   31200
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key23585488
Report Number9680794-2025-00951
Device Sequence Number13110873
Product Code DQY
UDI-Device Identifier10801902105339
UDI-Public(01)10801902105339(11)240709(17)280831(10)14F24G0075(21)
Combination Product (Y/N)N
Initial Reporter CountryPE
PMA/510(K) Number
K862056
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 10/23/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue NumberCV-15703
Device Lot Number14F24G0075
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/23/2025
Supplement Date Received by Manufacturer12/09/2025
Initial Report FDA Received Date11/18/2025
Supplement Report FDA Received Date12/18/2025
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured07/09/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NOT REPORTED; NOT REPORTED
Patient Age51 YR
Patient SexUnknown
-
-