| Catalog Number |
0606560 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Bacterial Infection (1735); High Pulmonary Arterial Wedge Pressure (2480); Bacteremia (4846)
|
| Date of Event |
10/21/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
On (b)(6) 2024, a patient underwent a chronic catheter placement procedure using the hickman cv catheter.1 years 9 months and 4 days post procedure the patient allegedly reported pulmonary hypertension cns and also treated for a staph aureus bacteremia and remains an inpatient.Iv flucloaxacillin and iv gentamicin given for the infection.Line was removed and replaced.The current status of the patient was unknown.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: as the lot number for the device was not provided, a review of the device history records could not be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.Section a through f ¿ the information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
On (b)(6) 2024, a patient underwent a chronic catheter placement procedure using the hickman cv catheter.One year nine months and four days post procedure the patient allegedly reported pulmonary hypertension cns and also treated for a staph aureus bacteremia and remains an inpatient.Iv flucloaxacillin and iv gentamicin given for the infection.Line was removed and replaced.The current status of the patient was unknown.
|
| |
|
Event or Problem Description
|
|
On (b)(6)2024, a patient underwent a chronic catheter placement procedure using the hickman cv catheter.1 years 9 months and 4 days post procedure the patient allegedly reported pulmonary hypertension cns and also treated for a staph aureus bacteremia and remains an inpatient.Iv flucloaxacillin and iv gentamicin given for the infection.Line was removed and replaced.The current status of the patient was unknown.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: additional information was received indicating that pulmonary hypertension and bacteremia occurred as part of a cascading sequence of events associated with the reported leakage and presence of a hole.Based on this information, the case was reassessed for reportability.As these events are considered part of a cascading sequence, the record is considered to be no longer reportable.However, since an initial mdr has already been submitted, the file will remain assessed as a serious injury.G3.Section a through f: the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: additional information was received indicating that pulmonary hypotension and bacteremia occurred as part of a cascading sequence of events associated with the reported leakage and presence of a hole.Based on this information, the case was reassessed for reportability.As these events are considered part of a cascading sequence, the record is considered to be no longer reportable.However, since an initial mdr has already been submitted, the file will remain assessed as a serious injury.G3:
section a through f: the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|