Model Number KD-VC631Q-07203S
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 10/28/2025
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that when using the single use preloaded sphincterotome during an endoscopic retrograde cholangiopancreatography, the physician noticed a mark or dot on the x-ray image.The device was taken out to be inspected, no damage was seen, and the device was inserted back into the scope.When the wire was inserted back into the biliary duct under x-ray, the mark or dot was gone.A small piece of metal was observed next to the duct.The physician noted that the piece of metal came from the wire, and that there was a piece missing at the junction of the soft part of the wire and wire core itself, which could be this piece of metal.The physician determined to leave the metal piece in place since it will be voided naturally.There were no reports of further patient harm.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE USE PRELOADED SPHINCTEROTOME V(DISTAL WIREGUIDED)
Common Device Name
SINGLE USE PRELOADED SPHINCTEROTOME
Manufacturer (Section D)
OLYMPUS VIETNAM CO. LTD.
8 street, long thanh ind. zone
an phuoc commune
dong nai province 81000 0
VM  810000
MDR Report Key23612332
Report Number2429304-2025-00300
Device Sequence Number9785630
Product Code KNS
UDI-Device Identifier04953170399503
UDI-Public04953170399503
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Importer
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial
Report Date (Section B) 11/20/2025
Report Date (Section F) 11/20/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberKD-VC631Q-07203S
Device Lot Number4YV
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date10/29/2025
Event Location Hospital
Date Report to Manufacturer10/29/2025
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date11/20/2025
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device A
Patient Sequence Number1
Patient Age22 YR
Patient SexFemale
Date Report Sent to FDA11/20/2025
-
-