U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY IRELAND STEM EXTRACTORDLE; EXTRACTION INSTRUMENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY IRELAND STEM EXTRACTORDLE; EXTRACTION INSTRUMENT Back to Search Results
Catalog Number 17601A
Medical Device Problem Code Material Deformation (2976)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/22/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Product complaint # (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported the device threads seemed to have cross threaded and were not functioning correctly.There was no patient or procedure involvement.
 
Additional Manufacturer Narrative
Product complaint # (b)(4) investigation summary item was reported for unknown reason.It did not happen in surgery.Additional information received; i noticed this at the office prior to sending out to a surgery.The threads seem to have cross threaded and were not functioning correctly.The product was returned to depuy synthes for evaluation.Visual analysis revealed that the stem extractordle exhibits an overall appearance of constant usage.Additionally, the threads of the bolt are cross-threaded.Functional testing revealed that both the threaded extractor bolt and nut were seized.Despite multiple attempts and the application of excessive force, the nut could not be rotated as intended due to bolt's threads condition.A dimensional inspection was not performed since it was not applicable to the complaint condition.The evaluation of the returned device, as well as previous failure analysis performed of related complaints (b)(4), found the failure of the mechanism was attributed to excessive loading applied to the stem extractor nut, which exceeded the local shear strength of the material.This condition resulted in thread deformation, fracture, and galling events.Consequently, these failures caused the seizing of the stem extractor nut and bolt, which could cause fracture of the stem extractor bolt during attempts to untighten the seized assembly.The overall complaint was confirmed as the observed condition of the stem extractordle would have contributed to the complained device issue.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.There is no indication that a design or manufacturing issue has caused the reported complaint condition.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history lot the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.H11 additional narrative: corrected: h3.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STEM EXTRACTORDLE
Common Device Name
EXTRACTION INSTRUMENT
Manufacturer (Section D)
DEPUY IRELAND
loughbeg ringaskiddy co.
cork
EI 
Manufacturer Contact
elba bello
700 orthopaedic dr.
warsaw, IN 46581
9083863534
MDR Report Key23616447
Report Number1818910-2025-20514
Device Sequence Number9988409
Product Code LXH
UDI-Device Identifier00197169176018
UDI-Public(01)00197169176018(10)PG351900
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number17601A
Device Lot NumberPG351900
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/04/2025
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/22/2025
Supplement Date Received by Manufacturer11/27/2025
Initial Report FDA Received Date11/21/2025
Supplement Report FDA Received Date12/01/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/10/2024
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-