|
A distributor reported on behalf of a healthcare facility in japan, via a fisher & paykel (f&p) healthcare field representative, that two 900mr869 temperature/flow probes were identified to be easily dislodged from a temperature probe port of an rt265 infant dual-heated evaqua2 breathing circuit during setup and prior to patient use.There was no reported patient harm.
|
|
A distributor reported on behalf of a healthcare facility in japan, via a fisher & paykel (f&p) healthcare field representative, that two 900mr869 temperature/flow probes were identified to be easily dislodged from a temperature probe port of an rt265 infant dual-heated evaqua2 breathing circuit during setup and prior to patient use.There was no reported patient harm.
|
|
(b)(4).Section d1: updated brand name.Section h11: method: the subject 900mr869 temperature/flow probes, rt265 infant dual-heated evaqua2 breathing circuit, and additional information about the reported event were requested to be provided to fisher & paykel (f&p) healthcare new zealand for evaluation.In addition, a review of the manufacturing records for the reported devices was completed.Results: the subject 900mr869 temperature/flow probes were received at f&p healthcare in new zealand for evaluation, where they were visually inspected.Visual inspection identified no visible damage or defects with the returned devices.A review of the manufacturing records for the reported 900mr869 temperature/flow probe lot batch was completed and confirmed that the patient-end temperature/flow probe parts were made to dimensional specifications.Further review of the manufacturing records of the rt265 infant dual-heated evaqua2 breathing circuit was not able to be performed as the healthcare facility reported that the lot information was unknown.Further assessment of 900mr869 temperature/flow probes was completed.The patient-end temperature probe part was measured and was within dimensional specification.Some variations were noted with measurements towards the lower end of the specification.The manufacturing processes of the patient-end temperature probe have been reviewed to reduce variation in dimensional specification.Conclusion: based on our investigation, the products were within specification.The reported event is likely to be related to dimensional variation at the patient-end temperature probe.As part of design validation and verification activities, all f&p healthcare products are tested to ensure they meet documented product requirements and specifications.At the end of the final assembly process, all 900mr869 temperature/flow probe are 100% tested as follows: functional testing of temperature/flow probe.Visual inspections for any visible defects and contamination.Resistance testing.At the end of the final assembly process, all rt265 infant dual-heated evaqua2 breathing circuits are 100% tested as follows: functional testing for leak.Visual inspections for any visible defects and contamination.Resistance testing of the heater wire.The instructions for use for the 900mr869 temperature/flow probes outlines the correct set-up of the temperature probe and also state the following: ensure that both temperature probe sensors are correctly and securely fitted.Push the airway probe and chamber probe into breathing circuit making sure they are correctly located and pushed into place.Perform ventilator leak test on the breathing circuit before use.There is a residual risk associated with use of this product, even if used as intended.Following all instructions and warnings provided, the risk of hypoxic injury, skin burns, airway burns, airway injury, lung injury, electric shock injury, musculoskeletal injury, and hypothermia remains.These risks may result in serious injury or death.The instructions for use accompanying each mr850 respiratory humidifier outlines the correct set-up of the device in accordance with instructions and warnings, and also states the following: ensure that both temperature probe sensors are correctly and securely fitted visually inspect the humidifier and accessories for damage before use and replace if damaged this product is for use under the supervision of trained medical personnel.Ensure that appropriate ventilator and/or patient monitor alarms are set, connections are secure and a leak test is completed before use.The mr850 technical manual also outlines the action required when a flashing 'airway probe' indicator is accompanied by an audible alarm, including to 'check for proper insertion of the airway probe into a correctly configured breathing circuit', and to 'adjust as necessary'.The technical manuals also outline the 6 monthly and annual maintenance tasks to ensure the humidifier, and its accessories are in working order.In addition, it also states that the accessories used with the mr850 respiratory humidifier are to be visually and functionally checked and replaced in the case of damage or if it fails the performance test.The instructions for use accompanying the rt265 infant dual-heated evaqua2 breathing circuits show in pictorial format the correct set-up of the circuit and also state the following: ensure appropriate ventilator or flow source alarms are set before connecting breathing set to patient perform a pressure and leak test on the breathing system and check for occlusions before connecting to a patient.Check all connections are tight before use appropriate patient monitoring (e.G.Oxygen saturation) must be used at all times.Failure to monitor the patient (e.G.In the event of an interruption to gas flow) may result in serious harm, or death.
|