| Model Number |
1103 |
| Medical Device Problem Code |
Material Integrity Problem (2978)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
11/24/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Investigation of this event is pending and a supplemental report will be sent upon its completion.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient had an old sheath repair from (b)(6) 2023.It was fraying, but there were no cracked areas exposed.The old repair was removed, and the driveline was assessed and photographed.A new repair was performed, covering all the cracks.The driveline cover was able to move freely back and forth after repair.The driveline remains in use.No patient complications have been reported as a result of this event.
|
| |
|
Additional Manufacturer Narrative
|
|
A supplemental report is being submitted for device evaluation.Product event summary: the driveline cable associated with (b)(6) was not returned for evaluation.A review of the device history records was not performed as the reported event and analysis are not related to a manufacturing issue.Review of (b)(6) service history records indicated that the device was previously serviced, and the repair actions were verified.On-site inspection of the driveline cable, as well as visual evidence provided by the site, revealed that the previous sheath repair was worn out and several new cracks beneath the previous repair.As a result, the reported event was confirmed.A driveline sheath repair was performed to mitigate the conditions reported.Based on the available information, the most likely root cause of the driveline repair damage may be attributed to factors such as normal wear over time and improper handling.The most likely root cause of the driveline sheath damage may be attributed to multiple factors including design issues and/or exposure to uv light.Investigation of this event is completed and the file will be closed.If new information is received, the file will be re-opened and a supplemental will be submitted.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Search Alerts/Recalls
|