TMJ SOLUTIONS, LLC DBA TMJ CONCEPTS TMJ BILATERAL IMPLANTS, OVERSIZED; PATIENT-FITTED TMJ RECONSTRUCTION PROSTHESIS Back to Search Results
Catalog Number CHG026
Medical Device Problem Code Nonstandard Device (1420)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/28/2025
Type of Reportable Event Malfunction
Event or Problem Description
Within the scope evaluation for a product field action, this case was identified to have the potential to exhibit the hazard of the recommended screw length being greater than the bone thickness for implants with screw holes located in an area of thin bone.No adverse consequences were reported for this event.
 
Additional Manufacturer Narrative
Device is not available for evaluation.If additional information is received, it will be reported on a supplemental report.
 
Additional Manufacturer Narrative
Additional information: the reported incident could not be confirmed.Stryker asked the customer to take note of the risks associated with this field action (which were mentioned in the customer notification).In this case, the surgeon confirmed that no adverse consequences were observed.
 
Event or Problem Description
No new information.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TMJ BILATERAL IMPLANTS, OVERSIZED
Common Device Name
PATIENT-FITTED TMJ RECONSTRUCTION PROSTHESIS
Manufacturer (Section D)
TMJ SOLUTIONS, LLC DBA TMJ CONCEPTS
6059 king drive
ventura 93003
Manufacturer (Section G)
TMJ SOLUTIONS, LLC DBA TMJ CONCEPTS
6059 king drive
ventura 93003
Manufacturer Contact
verena baumgartner-kis
boetzingerstr. 41
freiburg D-791-11
GM   D-79111
7614888208
MDR Report Key23716343
Report Number0002031049-2025-00092
Device Sequence Number21078313
Product Code LZD
UDI-Device Identifier07613327626568
UDI-Public07613327626568
Combination Product (Y/N)N
Initial Reporter CountryGM
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/27/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue NumberCHG026
Device Lot Number2306091054
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/26/2025
Supplement Date Received by Manufacturer11/26/2025
Initial Report FDA Received Date12/04/2025
Supplement Report FDA Received Date03/30/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-