MAUDE Adverse Event Report: MEDOS INTERNATIONAL SARL CORTICAL FXATION FXD LOOP 25MM; FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDOS INTERNATIONAL SARL CORTICAL FXATION FXD LOOP 25MM; FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE Back to Search Results
Catalog Number 232014
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/01/2025
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during a cruciate ligament reconstruction surgical procedure, when using the cortical fxation fxd loop 25mm suture device, it was observed that the suture broke off when it was tightened.It was reported that another device was used to complete the surgery.There were no adverse consequences to the patient.No additional information could be provided.
 
Additional Manufacturer Narrative
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Device was used for treatment, not diagnosis.H11 additional narrative: investigation summary the product was not returned to depuy synthes, however a photo was provided for evaluation.Visual inspection of the returned photo found that the device is shown in used condition.The white suture was found broken and frayed.An investigation was made with the manufacturer; as a result, the white suture is utilized to assembly onto a graft construction which provides fixation.The green/white suture works as the lead suture for pulling the implant/graft construction with tension, the tension values are associated with this final implant assembly; the strength requirement for the sutures are 250n clinical spec ~1700n.The clinical spec tension is high compared with the expected intraoperative loads of 20-50n.Therefore, based on the work instruction of finish goods, the tension is measured only on the green/white suture during the manufacturing process.Since the white suture is broken and considering the damaged condition, a pull test is not required.Regarding the white suture, an inspection is performed during the manufacturing process to verify its size and condition, this information corresponds with the process control, and its record guarantees the white suture inspection.Since the suture breakage couldn't be originated during manufacturing process, the breakage can be attributed to procedure variables such as excessive counter tension or other instrument that pulls the white suture which creates a stress point on the suture, leading to a breakage.As per the instructions for use (ifu) the steps for a proper insertion are provided.The overall complaint was confirmed as the observed condition of the cortical fxation fxd loop 25mm would have contributed to the complained device issue.Based on the investigation findings, the potential cause is traced to procedure variables such as excessive counter tension or other instrument that pulls the white suture which creates a stress point on the suture, leading to a breakage.As per ifu the steps for a proper insertion are provided.It has been determined that no corrective and/or preventative action is required.There is no indication that a design or manufacturing issue has caused the reported complaint condition.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CORTICAL FXATION FXD LOOP 25MM
Common Device Name
FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE
Manufacturer (Section D)
MEDOS INTERNATIONAL SARL
chemin-blanc 38
le locle 02400
SZ  02400
Manufacturer (Section G)
MEDOS INTERNATIONAL SARL
chemin blanc 38
le locle CH-24 00
SZ   CH-2400
Manufacturer Contact
elba bello
325 paramount drive
raynham, MA 02767
9083863534
MDR Report Key23778405
Report Number1221934-2025-04716
Device Sequence Number10083942
Product Code MBI
UDI-Device Identifier10886705022663
UDI-Public(01)10886705022663(10)169L601(17)260430
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K130814
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/30/2026
Device Catalogue Number232014
Device Lot Number169L601
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/02/2025
Initial Report FDA Received Date12/11/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured05/09/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-