| Model Number |
HEM3335 |
| Medical Device Problem Code |
Mechanics Altered (2984)
|
| Health Effect - Clinical Codes |
Hemorrhage/Blood Loss/Bleeding (1888); Tissue Breakdown (2681)
|
| Date of Event |
05/28/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
According to the reporter during a procedure for the treatment of hemorrhoids, the device failed to properly place staples, resulting in a significant section of the rectal mucosa being cut.The issue caused substantial rectal bleeding, specifically in about 2/3 to 3/4 of the circumference of the mucosal area.The surgeon attempted to control the bleeding by suturing the mucosal edges and performing targeted hemostasis over the bleeding section.
|
| |
|
Additional Manufacturer Narrative
|
|
Correction: b5 medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
According to the reporter, during a procedure for the treatment of hemorrhoids, the device failed to place staples, performed only the section, resulting in a significant section of the rectal mucosa being cut.The issue caused substantial rectal bleeding, specifically in about 2/3 to 3/4 of the circumference of the mucosal area.The surgeon attempted to control the bleeding by suturing the mucosal edges and performing targeted hemostasis over the bleeding section.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: g3, h6 h3 evaluation summary: medtronic conducted an investigation based upon all information received.The device was available for evaluation.Visual inspection noted that the visual inspection of the staple guide noted the instrument was fully applied.Further inspection noted that the green bar was not visible in the indicator window and the safety feature was not engaged.The staple guide was observed to be attached to the instrument with no damage to the staple guide.After actuating the handle, the pusher fingers appeared to be intact and inspection under the microscope displayed no damage to the knife blade.{anvil}.The anvil of the instrument was observed to be separated from the instrument.Further inspection of the anvil cutting ring showed deep traces of knife impression and the ring was received completely severed.An acceptable gap between anvil and staple guide was observed when fully approximated.It was reported that staples did not deploy.The reported issue could not be confirmed.The most likely cause could not be established from the information available.The manufacturing records for each device are thoroughly reviewed prior to release to ensure that it meets all medtronic quality specifications.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|