MAUDE Adverse Event Report: THORATEC CORPORATION HEARTMATE® POWER MODULE (N/A); VENTRICULAR (ASSIST) BYPASS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

THORATEC CORPORATION HEARTMATE® POWER MODULE (N/A); VENTRICULAR (ASSIST) BYPASS Back to Search Results
Model Number 1340
Medical Device Problem Codes Mechanical Problem (1384); Use of Device Problem (1670)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/02/2025
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that power module red battery was active and did not resolve.There probably was some physical damage to the unit.
 
Additional Manufacturer Narrative
No further information was provided.A supplemental report will be submitted once the manufacturer¿s investigation is completed.
 
Additional Manufacturer Narrative
Section g4: there was no patient involved in this event.The pma # provided is associated with the device¿s most recent approval.Manufacturer's investigation conclusion: the reported event of a red battery alarm produced on the returned power module could not be confirmed; however, the reported event of physical damage to the housing was confirmed through analysis of the returned product.The heartmate power module (serial number (b)(6)) was inspected at the service depot.The ppm underwent functional checkout and passed all tests.No yellow wrench or red battery faults were reproduced throughout testing.The power module was returned to the customer site ready for use.The root cause for the reported events was unable to be conclusively determined through this analysis.Device history records were reviewed and showed no deviations from manufacturing or quality assurance (qa) specifications.The current revision of the instructions for use (ifu) can be found on the eifu page of the abbott website.The heartmate 3 ifu (rev.D), section 7 - ¿alarms and troubleshooting¿, and heartmate 3 patient handbook (rev.A), section 5 - ¿alarms and troubleshooting¿, explain how to properly interpret and troubleshoot atypical alarms.The heartmate 3 ifu, section 3 - ¿powering the system¿, states that the power module contains an internal backup battery that provides approximately 30 minutes of backup power to the system during a power emergency.It instructs to keep the power module plugged into ac power at all times to make sure that the power module backup battery is charged and ready for use in case of power interruption.If the power module is without ac power for approximately 18 hours or more, the power module backup battery may be damaged.Additionally, it is stated that if the power module backup battery is not installed or connected when the power module is plugged in, the power module alarms, indicating that it cannot provide backup power in the event of a power interruption.The heartmate power module ifu (rev.B) (section 11.0 ¿routine maintenance¿) instructs users to bring their power module to an authorized service technician at least once per year for a thorough inspection and cleaning.Routine maintenance also includes the unit¿s internal backup battery being replaced.Heartmate 3 ifu, section 4 - ¿system monitor¿, and heartmate 3 patient handbook, section 6 - ¿caring for the equipment¿, explain how to properly handle the power module and cables to prevent damage.The patient handbook cautions the users to call their hospital contacts if they think, for any reason, any portion of their equipment is not functioning as usual, is broken, or they are uncomfortable with the operation of the equipment.No further information was provided.The manufacturer is closing the file on this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HEARTMATE® POWER MODULE (N/A)
Common Device Name
VENTRICULAR (ASSIST) BYPASS
Manufacturer (Section D)
THORATEC CORPORATION
6035 stoneridge drive
pleasanton CA 94588
Manufacturer (Section G)
THORATEC CORPORATION
6035 stoneridge drive
pleasanton CA 94588
Manufacturer Contact
fredric gold
6035 stoneridge drive
pleasanton, CA 94588
7818528207
MDR Report Key23812538
Report Number2916596-2025-07956
Device Sequence Number21157038
Product Code DSQ
UDI-Device Identifier00813024010654
UDI-Public(01)00813024010654(11)130101
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
P160054
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date (Section B) 02/25/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number1340
Device Catalogue Number1340
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/02/2025
Supplement Date Received by Manufacturer02/24/2026
Initial Report FDA Received Date12/15/2025
Supplement Report FDA Received Date02/25/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/01/2013
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-