| Catalog Number |
123616A |
| Medical Device Problem Code |
Material Rupture (1546)
|
| Health Effect - Clinical Code |
Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
12/11/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.This report references a us equivalent device.The us udi equivalent for this product number is used.H11: sections a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2025, in the afternoon, the patient in bed 35 underwent bladder hematoma removal surgery.After the operation, an 18-french three-way foley catheter was indwelled for continuous bladder irrigation.About 2 hours postoperatively, the patient suddenly felt an explosive sensation in the lower abdomen, after which the catheter was spontaneously expelled.Upon examination, the doctor found that the catheter balloon had ruptured, and the catheter was subsequently reinserted.The balloon rupture occurred immediately after the bladder hematoma removal surgery, and the reinsertion of the catheter caused harm to the patient.
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event was inconclusive because no sample was returned.It is unknown whether the device had met relevant specifications.The product was used for urological care.It was unknown whether the product had caused the reported failure.A potential root cause for this failure mode could be user related (example: contact with sharp object/ exposure to petrolatum based products mechanical failure/operator error).The labeling and instructions for use were found to be adequate.A review of the device history record did not show any problems or conditions that would have contributed to the reported issue.Therefore, no additional action required at this time.Correction: d this report references a us equivalent device.The us udi equivalent for this product number is used.H11: sections a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2025, in the afternoon, the patient in bed 35 underwent bladder hematoma removal surgery.After the operation, an 18-french three-way foley catheter was indwelled for continuous bladder irrigation.About 2 hours postoperatively, the patient suddenly felt an explosive sensation in the lower abdomen, after which the catheter was spontaneously expelled.Upon examination, the doctor found that the catheter balloon had ruptured, and the catheter was subsequently reinserted.The balloon rupture occurred immediately after the bladder hematoma removal surgery, and the reinsertion of the catheter caused harm to the patient.
|
| |
|
Search Alerts/Recalls
|