W. L. GORE & ASSOCIATES, INC. GORE® EXCLUDER® AAA ENDOPROSTHESIS; SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
|
Back to Search Results |
|
| Catalog Number |
PLC161000 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Obstruction/Occlusion (2422)
|
| Date of Event |
11/24/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
The following was reported to gore: on (b)(6) 2025, a patient was treated for an aortic aneurysm using a gore® excluder® thoracoabdominal branch endoprosthesis (tambe), including 3 gore® excluder® aaa endoprosthesis contralateral leg devices (plc).Reportedly, the physician had previously tried open repair and was reintervening because the aorta was rejecting the open repair.On (b)(6) 2025, a reintervention took place.A degenerative thrombus had developed just distal to the right-side plc.A gore® excluder® aaa endoprosthesis contralateral leg device was used to extend into the right external iliac, covering and coiling the right internal iliac artery, and covering the degenerative thrombus.Images are available.Reportedly, the physician attributes the thrombus to the interaction between the devices and the patient's connective tissue disorder.
|
| |
|
Additional Manufacturer Narrative
|
|
H.6.Investigation findings code c21: conclusions pending results of product history review and imaging evaluation.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Additional Manufacturer Narrative
|
|
H.6.Type of investigation code b20: the device remains implanted and is not available for analysis.H.6.Investigation findings code c19: a review of the manufacturing records for the device verified that the lot met all pre-release specifications.H.6.Type of investigation code b15: a review of images confirmed the presence of the degenerative thrombus, but was not able to confirm the cause or the reintervention.
|
| |
|