Model Number N161
Medical Device Problem Codes Delayed Charge Time (2586); Battery Problem (2885)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/18/2025
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that this cardiac resynchronization therapy defibrillator (crt-d), with 8 months of remaining longevity, had reached the elective replacement indicator (eri) and is now at end of life (eol).Technical services (ts) reviewed the case and confirmed that eri was triggered due to charge time (ct).Ts also stated that the patient likely experienced a connection problem; otherwise, the alert would have been sent via latitude.This device remains in service.No adverse patient effects were reported.Additional information was received stating this device was explanted and replaced.No additional adverse patient effects were reported.
 
Additional Manufacturer Narrative
If pertinent information is provided in the future, a supplemental report will be submitted.
 
Additional Manufacturer Narrative
This product was explanted and has not been returned to boston scientific, and as a result, laboratory analysis could not be conducted.It was confirmed that this device met manufacturing specifications prior to distribution and there was no indication that the device manufacturing process contributed to the reported complaint.A review of the device history record (dhr) was performed.The review of the dhr identified that there were no process related non-conformances, scrap, or rework performed during the production that could explain the event.The reviews ensure each device meets specification prior to release for use.There is no indication the device manufacturing process contributed to the reported complaint.A risk review was completed and confirmed that the event of delayed charge time was defined in the risk documentation.This event type has been accounted for during product risk analysis to support acceptable risk benefit for the product.Review of labeling determined that the complaint situation was listed in the manual.There was no indication in the complaint that the product was not used in accordance to labeling.The manual was unlikely to be the cause of the reported complaint; translation, wording, or graphics does not require further review.Based on a thorough review of the reported complaint, boston scientific has assigned an investigation conclusion code of device problem excluded.If pertinent information is provided in the future, a supplemental report will be submitted.
 
Event or Problem Description
It was reported that this cardiac resynchronization therapy defibrillator (crt-d), with 8 months of remaining longevity, had reached the elective replacement indicator (eri) and is now at end of life (eol).Technical services (ts) reviewed the case and confirmed that eri was triggered due to charge time (ct).Ts also stated that the patient likely experienced a connection problem; otherwise, the alert would have been sent via latitude.This device remains in service.No adverse patient effects were reported.Additional information was received stating this device was explanted and replaced.No additional adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INCEPTA? CRT-D
Common Device Name
CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
cashel road
clonmel
EI  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key23860155
Report Number2124215-2025-92184
Device Sequence Number17310640
Product Code LWP
UDI-Device Identifier00802526481000
UDI-Public(01)00802526481000(17)160725
Combination Product (Y/N)N
Initial Reporter StateLA
Initial Reporter CountryUS
PMA/510(K) Number
P010012
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Device Explanted Year2025
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/20/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date07/25/2016
Device Model NumberN161
Device Catalogue NumberN161
Device Lot Number501762
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/20/2025
Supplement Date Received by Manufacturer03/18/2026
Initial Report FDA Received Date12/20/2025
Supplement Report FDA Received Date03/20/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured07/31/2014
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;