| Catalog Number |
CQ5074 |
| Medical Device Problem Code |
Material Rupture (1546)
|
| Health Effect - Clinical Codes |
Vascular Dissection (3160); Foreign Body Embolism (4439); No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
09/24/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
On (b)(6) 2025, a patient underwent a percutaneous transluminal angioplasty (pta) procedure for vascular stenosis using the conquest balloon catheter.During the procedure, it was reported that the balloon catheter allegedly ruptured.As a result, the surgery was interrupted with delayed treatment and also posed risks of complications such as vascular embolism and intimal tear due to residual balloon debris.The procedure was completed using another device.Current status of the patient is unknown.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: as the lot number for the device was provided, a review of the device history records was performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.Section a through f ¿ the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: additional information was received, and the file was reassessed for reportability and determined to be reportable as malfunction.Manufacturing review: the device history records have been reviewed and this lot met all release criteria.Investigation summary: the physical device was not returned for evaluation.No photos were provided for review.Therefore, the investigation is inconclusive for the reported failure as no objective evidence was provided for review.A definitive root cause for the reported balloon rupture could not be determined based upon the provided information.Labeling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.B1, b2 (event attributed to), b5, g3, h1, h6 (patient).Section a through f ¿ the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
On (b)(6) 2025, a patient underwent a percutaneous transluminal angioplasty (pta) procedure for vascular stenosis using the conquest balloon catheter.During the procedure, the balloon catheter allegedly ruptured.As a result, the surgery was interrupted with delayed treatment and also posed risks of complications such as vascular embolism and intimal tear due to residual balloon debris.The procedure was completed using another device.There was no reported patient injury.
|
| |
|