ARTHREX, INC. BIO-COMP SWIVELOCK C, CLD 5.5X19.1MM; BIO SOFT TISSUE FIXATN FASTNR Back to Search Results
Model Number BIO-COMP SWIVELOCK C, CLD 5.5X19.1MM
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/12/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Event or Problem Description
On 11th dec 2025, it was reported by an arthrex's employee via an email that for 2 units of ar-2323bcc, suture anchor, biocomposite swivelock® c, 5.5 mm x 19.1 mm, closed eyelet, 1 unit of the anchor pulled out when retrieving the pole.Another ar-2323bcc was changed to and its anchor broke during insertion.This was detected during a rotator cuff repair surgery on (b)(6) 2025.The procedure was completed successfully by using the third ar-2323bcc.There were no patient harm and no secondary procedure needed.
 
Additional Manufacturer Narrative
Additional information: d9, g3, h3, h6.Complaint allegation is confirmed.Visual inspection of the anchor of the suture anchor, biocomposite swivelock® c, 5.5 mm x 19.1 mm, closed eyelet, was broken and damaged.Functional testing was not performed due to the damage to the device.Per dfu-0087-eo - g.Precautions - 3.Make sure to use the recommended drill bit or punch to create the bone socket.4.Pushlock and swivelock suture anchors only: during anchor insertion, ensure that the angle of anchor insertion is coaxial to that of the previously prepared bone socket.The most likely cause of the reported failure can be attributed to user error with the device due to misalignment and excessive force applied during insertion, and/or prying/leveraging of the device during use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BIO-COMP SWIVELOCK C, CLD 5.5X19.1MM
Common Device Name
BIO SOFT TISSUE FIXATN FASTNR
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key23934860
Report Number1220246-2025-05930
Device Sequence Number9627376
Product Code MAI
UDI-Device Identifier00888867026728
UDI-Public(01)00888867026728(11)241217(17)281130(10)15363203
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K203495
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Company Representative
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 04/13/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberBIO-COMP SWIVELOCK C, CLD 5.5X19.1MM
Device Catalogue NumberAR-2323BCC
Device Lot Number15363203
Was Device Available for Evaluation? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/11/2025
Supplement Date Received by Manufacturer04/10/2026
Initial Report FDA Received Date12/31/2025
Supplement Report FDA Received Date04/13/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured12/17/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-