Catalog Number 501420
Medical Device Problem Code Malposition of Device (2616)
Health Effect - Clinical Codes Erosion (1750); Micturition Urgency (1871); Pain (1994); Urinary Retention (2119); Urinary Tract Infection (2120); Urinary Frequency / Polyuria (2275); Hematuria (2558); Intermenstrual Bleeding (2665); Dysuria (2684); Dyspareunia (4505); Cramp(s) /Muscle Spasm(s) (4521); Urinary Incontinence (4572); Pelvic Pain (4865)
Date of Event 10/28/2024
Type of Reportable Event Serious Injury
Event or Problem Description
As reported to coloplast, though not verified: the patient reportedly had a supris and restorelle y implanted in (b)(6) 2019.Subsequently, the patient experienced hematuria, mesh erosion at right lateral wall/bladder neck encrusted with stone, pelvic pain, right hip pain and recurrent urinary tract infections.The patient underwent examination under anesthesia, partial controlled cystectomy and cystoscopy.Robotic assisted removal of right arm of mesh was performed (complex/tedious) and cystotomy repair with 2 layer closure was performed.Intraoperative findings included right sling arm malpositioned lying along right anterior bladder wall and aimed high up in abdominal wall with no exit point (~8 cm above normal suprapubic exit point), mesh attached to bladder on right side with associated calcifications into bladder wall posterior and lateral to right ureteral orifice.
 
Additional Manufacturer Narrative
The lot number was reviewed for complaint trend, nonconforming report and capa.Devices met specification prior to release.No trends were noted for complaints and there were no nonconforming reports or capas that were confirmed in veeva to be associated.The device was not returned for evaluation.Without the benefit of analyzing the device, coloplast cannot comment on the condition of the device.Should additional information prompt us to alter or supplement any information or conclusions contained in this report, a follow-up report will be submitted.
 
Event or Problem Description
As additionally reported to coloplast, though not verified, the patient also experienced urinary urgency/frequency, nocturia, feeling of incomplete bladder emptying, random blood in toilet after sex, dysuria after sex, urinary tract infections resistant to antibiotics, dyspareunia, persistent urethral burning (worse in am then improves), recurrent stress urinary incontinence with full bladder, left hip pain and muscle spasm/ high-tone pelvic floor dysfunction.
 
Additional Manufacturer Narrative
This complaint was investigated to the extent information was provided to coloplast.Due to the legal nature of this complaint and the device not being returned for evaluation a thorough investigation could not be executed.Should additional information become available, this file will be re-evaluated and updated according to current procedures.Complaints of this nature are monitored and captured within the product risk documentation.No further action or corrective action is required at this time.D10: 51956 supris retropubic kit.Therapy date (b)(6)2019.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RESTORELLE POLYPROPYLENE MESH FOR SACROCOLPOPEXY, SACROCERVICOPEXY, AND SACROHYS
Common Device Name
PELVIC ORGAN PROLAPSE SURGICAL MESH, SYNTHETIC POLYMER
Manufacturer (Section D)
COLOPLAST A/S
1 holtedam humlebaek, dk 3050
humlebaek 3050
DA  3050
Manufacturer (Section G)
MINNEAPOLIS
Manufacturer Contact
usbes brian schmidt
1601 west river road n
minneapolis, MN 55411
MDR Report Key23960021
Report Number2125050-2026-00012
Device Sequence Number21235206
Product Code OTO
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K132061
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2019
Device Explanted Year2025
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 05/21/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/24/2021
Device Catalogue Number501420
Device Lot Number6427315_5014202400
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer Not provided
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date01/05/2026
Supplement Report FDA Received Date05/21/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured11/14/2018
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age41 YR