| Catalog Number |
451570107 |
| Medical Device Problem Codes |
Device Slipped (1584); Device-Device Incompatibility (2919)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
12/30/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H10 additional narrative: as of this date, the device has not been returned for evaluation; therefore, the reported condition cannot be confirmed and/or duplicated.
|
| |
|
Event or Problem Description
|
|
It was reported that during a total knee arthroplasty surgical procedure, while using six (x6) robotic assisted array clamp devices with two (x2) robotic assisted satellite station devices, and a robotic assisted saw handpiece device, it was observed that the connection was loose causing saw cutouts.It was also reported that the arrays were popping out of the clamps.There were no delays in the procedure reported.There were no injuries, medical intervention or prolonged hospitalization.All available information has been disclosed.This is 6 of 6 for the same event.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.H11 additional narrative: d9, h3, h6: the actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.H11 additional narrative: investigation summary: the velys array clamp was returned to depuy synthes for evaluation.The lot number of the subcomponent was different.Visual analysis of the returned device found that the velys array clamp presents an overall worn appearance consistent with multiple uses.No signs of damage nor defects that could have affect the functionality were observed.A dimensional inspection was not performed since it was not applicable to the complaint condition.A functional test was performed using depuy synthes samples as mating components.The assessment revealed mating component could be assembled and hold as intended, with no sign of undesired movement or resistance on the process.The overall complaint was not confirmed as the observed condition of the velys array clamp would not contribute to the complained device issue.
|
| |
|
Search Alerts/Recalls
|