BIOSENSE WEBSTER INC THERMOCOOL SMARTTOUCH; CARDIAC ABLATION PERCUTANEOUS CATHETER Back to Search Results
Catalog Number D133602
Medical Device Problem Codes Incorrect, Inadequate or Imprecise Result or Readings (1535); Contamination /Decontamination Problem (2895)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device evaluation details.The smart touch unidirectional device was returned to johnson & johnson medtech (j&j medtech) for evaluation on (b)(6) 2025.A visual inspection and screening test of the returned device were performed following j&j medtech procedures.Visual analysis revealed reddish material and a hole in the surface of the pebax.The device was connected to the carto 3 system and no errors were observed.The force feature of the device was evaluated and the force values and the vector were observed within specifications.No force issues were observed.A manufacturing record evaluation was performed for the finished device batch number, and no internal actions were identified.The reddish material inside the pebax could be related to the force issue reported by the customer; therefore, the customer complaint was confirmed.The root cause of the pebax damage could be related to the manipulation of the device during the procedure; however, this cannot be conclusively determined.The instruction for use states: when cleaning the tip electrode, be careful not to twist the tip electrode with respect to the catheter shaft; twisting may damage the tip electrode bond and loosen the tip electrode, or may damage the contact force sensor.In addition, in order to prevent damage to the catheter tip, use the insertion tube supplied with the catheter to advance or retract the catheter through the hemostasis valve of the sheath.After insertion, slide the insertion tube back toward the handle.As part of j&j medtech¿s quality process, all devices are manufactured, inspected, and released to approved specifications.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster, inc., or its employees that the report constitutes an admission that the product, biosense webster, inc., or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Manufacturer's reference number:(b)(4).
 
Event or Problem Description
It was reported that a patient underwent a cardiac ablation procedure with a thermocool smarttouch catheter for which biosense webster¿s product analysis lab (pal) identified a hole in the surface of the pebax.The contact of the catheter was not coherent during the procedure.It always detected a contact with a catheter even if it was the only catheter into the atrium.We changed first the cable, a new catheter resolved the issue.We also saw some blood in the rotor of the defective catheter.No patient consequence.The biosense webster, inc.Product analysis lab received the device for evaluation and per the evaluation completion on (b)(6) 2025 observed reddish material and a hole in the surface of the pebax.The event was originally considered non-reportable, however, bwi became aware of a hole in the surface of the pebax on (b)(6) 2025 and have assessed this returned condition as reportable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
THERMOCOOL SMARTTOUCH
Common Device Name
CARDIAC ABLATION PERCUTANEOUS CATHETER
Manufacturer (Section D)
BIOSENSE WEBSTER INC
31 technology drive, suite 200
irvine CA 92618
Manufacturer (Section G)
BIOSENSE WEBSTER INC (JUAREZ)
circuito interior norte
1820parque industrial salvacar
juarez 32599
MX   32599
Manufacturer Contact
henry boden
31 technology dr
irvine, CA 92618
9497882078
MDR Report Key24070043
Report Number2029046-2026-00150
Device Sequence Number21403038
Product Code LPB
UDI-Device Identifier10846835009002
UDI-Public(01)10846835009002(17)280607(10)31651489M
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
P030031/S053
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 01/14/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberD133602
Device Lot Number31651489M
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/08/2025
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/17/2025
Initial Report FDA Received Date01/14/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured06/08/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
UNK CABLE.
Patient SexUnknown
-
-