| Catalog Number |
42521400413 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Pain (1994); Loss of Range of Motion (2032); Joint Laxity (4526)
|
| Date of Event |
10/27/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).D10: 42500805802 - femur trabecular metal posterior stabilized (ps) standard porous - 64317695.G2: foreign country: united kingdom.Customer has indicated that the product will not be returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.
|
| |
|
Event or Problem Description
|
|
It was reported from an external clinical study that a patient underwent an initial right total knee arthroplasty without patellar replacement.Subsequently, the patient underwent an arthroscopy approximately 10 months post-op due to pain, poor range of motion, and stiffness.During the exam, full range of motion was achieved with no need for a manipulation.The knee was stable in full extension, but some laxity was observed in flexion.A steroid injection in the it band provided temporary relief; however, the patient later reported continued instability in flexion and the knee was successfully revised approximately 2.5 years post-op.During the revision, the preop exam under anesthesia revealed restriction to full extension with mid flexion instability and increased laxity in full flexion.The tibial and femoral implants were found well fixed and in good condition.Grade iii osteoarthritic changes were observed on the native patella with a large hooked osteophyte removed prior to resurfacing.All implants were exchanged, and a patellar button was implanted without complications.Attempts have been made and all available information has been provided.
|
| |
|
Event or Problem Description
|
|
No further event information available at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.The following sections were updated:
b4; b5; d2; g1; g3; g6; h1; h2; h3; h6.The event is confirmed.No product was returned, or pictures provided; visual and dimensional evaluations could not be performed.The device history record was reviewed and no discrepancies relevant to the reported event were found.Review of complaint history found no additional related issues for this item and the reported part and lot combination.Medical records were provided and reviewed by a health care professional.Review of the available records identified the following: participant suffered from stiffness and poor rom and subsequently underwent a mua.At the time of the mua, the participant underwent an arthroscopy to obtain samples.No indication of infection or loosening to account for participants pain and stiffness symptoms.Participant had a steroid injection into it band which provided 2 weeks of relief from symptoms.Ct and bone scans of knee was normal yet suggest the implant had 1° of internal rotation of the femur, and 3° of internal rotation of the tibia.Implant sizing looked satisfactory.Patient described that they felt unstable in flexion and may have hyper mobility.Decision was made to revise tka.Eua found full rom with no manipulation required.Knee stable in full extension at 20 degree flexion, definite medio-lateral laxity felt about 3-4 mm.At 90 degrees, no obvious lift off appreciated.Attempts to replicate complaint of femoral lurching when extending knee while on side unable to produce any instability.Arthroscopy showed no abnormalities.Steroid injection given as planned for scar prophylaxis.Single stage revision tka was undertaken and was successful.A definitive root cause cannot be determined.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Search Alerts/Recalls
|