• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SYNTHES GMBH DRILLSL Ø3.2 F/LOAD POSITION F/PERIARTI-; GUIDE, SURGICAL, INSTRUMENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SYNTHES GMBH DRILLSL Ø3.2 F/LOAD POSITION F/PERIARTI-; GUIDE, SURGICAL, INSTRUMENT Back to Search Results
Catalog Number 03.120.018
Medical Device Problem Code Device-Device Incompatibility (2919)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Event or Problem Description
It was reported multiple devices are no longer functional.These issues did not impact patient outcomes.Below devices were found to be "release mechanism broken" during inspection: 03.043.028.Below devices were found to be "stripped threads" during inspection: 03.120.022, 312.648, 323.029.Below devices were found to be "nut stuck on sleeve" during inspection: 03.037.017, 03.037.016.Below devices were found to be "handle leaching/spd wil not sterilize" during inspection: 03.100.018.Below devices were found to be "broken handle" during inspection: 311.43 below devices were found to be "stripped drill connection and 2nd is cold welded to a schanz pin" during inspection: 393.103.Below devices were found to be "broken sliding mechanism" during inspection: 319.091.Below devices were found to be "not snapping in" during inspection: 03.120.018, 03.120.017.Below devices were found to be "stripped" during inspection: 03.010.151, 314.467, 03.900.042, 03.130.010, 314.453, 03.010.150, 03.010.152.Below devices were found to be "not working properly" during inspection: 329.15.Below devices were found to be "not locking tension between trigger pulls" during inspection: 03.221.015.Below devices were found to be "not aligned" during inspection: 398.65.Below devices were found to be "not locking into aiming arm" during inspection: 03.231.007.Below devices were found to be "bent handle" during inspection: 393.1.Below devices were found to be "trigger detached from handle" during inspection: 03.221.007 below devices were found to be "not sliding properly" during inspection: 319.006.Below devices were found to be "shaft pulls out of handle" during inspection: 314.118.Below devices were found to be "not locking on" during inspection: 351.16j.Below devices were found to be "binding on qc attachments" during inspection: 511.773.Below devices were found to be "ends not aligning" during inspection: 03.221.011.(b)(4) is the mother complaint.(b)(4) are related to each other and are created to capture additional ips.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803 (and/or part 4, as applicable).This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.Additional narrative: d4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H11 additional narrative: added: b5.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
Additional information received: a.Date of event (mm/dd/yyyy): - items identified at various times in preop testing over the last few months.
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H11 additional narrative: added: d4 lot, d9.Corrected: d4 primary udi number.The device was received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H11 additional narrative: added: d10, h4.Corrected: g1.H3, h6: the product was returned to depuy synthes for evaluation.The depuy synthes team conducted a visual inspection of the returned device.Visual analysis of the returned sample revealed that drillsl ø3.2 f/load position f/periarti- exhibited normal signs of use.General corrosion was observed in the lot-number area; however, this condition should not affect the functionality of the device.Corrosion: the potential cause is being attributed to cleaning/sterlization methods.As per se_023827 rev ap, during cleaning, only use cleaning agents that are labelled for use on medical devices and in accordance with the manufacturer¿s instructions (e.G.Temperature, contact time, and rinse time).Cleaning agents with a used dilution ph of within 7¿9.5 are recommended.Highly alkaline conditions (ph >11) can damage components/devices, such as aluminum materials.Do not use saline, environmental disinfection (including chlorine solutions) or surgical antiseptics (such as iodine- or chlorhexidine-containing products).Do not use a cleaning aid that can damage the surface of instruments such as steel wool, abrasive cleaners or wire brushes.A dimensional inspection for the drillsl ø3.2 f/load position f/periarti- was not performed as it is not aplicable to reported conditin.A complete functional test was unable to performed as the mating device was not received to assess the interaction, however; the release spring was press and work as expected, no issues were identified.The overall complaint was not confirmed as the observed condition of the drillsl ø3.2 f/load position f/periarti- would not contribute to the complained device issue.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.There is no indication that a design or manufacturing issue has caused the complaint condition.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history lot: part:03.120.018, synthes lot: 1989846, supplier lot: 1989846, release to warehouse date: oct 03, 2008, manufactured by: synthes gmbh oberdorf.No ncrs were generated during production.Device history review: review of the device history record(s) showed that there were no issues during the manufacture of this product, and any sub-components, which would contribute to this complaint condition.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DRILLSL Ø3.2 F/LOAD POSITION F/PERIARTI-
Common Device Name
GUIDE, SURGICAL, INSTRUMENT
Manufacturer (Section D)
SYNTHES GMBH
luzernstrasse 19-21
zuchwil 4528
SZ  4528
Manufacturer (Section G)
OBERDORF : SYNTHES PRODUKTIONS GMBH
eimattstrasse 3
oberdorf CO
SZ  
Manufacturer Contact
elba bello
1302 wright lane east
west chester, PA 19380
9083863534
MDR Report Key24182905
Report Number8030965-2026-00892
Device Sequence Number15842166
Product Code FZX
UDI-Device Identifier10886982074164
UDI-Public(01)10886982074164(10)1989846
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup,Followup
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number03.120.018
Device Lot Number1989846
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 01/12/2026
Supplement Date Received by Manufacturer01/28/2026
02/17/2026
03/04/2026
Initial Report FDA Received Date01/26/2026
Supplement Report FDA Received Date02/06/2026
03/03/2026
03/10/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/03/2008
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
2.8MM THREADED DRILL GUIDE.; ADAPT F/SELDRILL SCHANZ SCR Ø5.; BENDING PLIERS FOR 2.7MM & 3.5MM PLATES.; DEPTH GAUGE FOR 2.0MM AND 2.4MM SCREWS.; DRIVING CAP.; HANDLE F/NOS. 324.203+324.215.; LCP DRILL SLEEVE 2.4 W/SCAL-30 F/DRILL B.; NEUTRAL DRILL GUIDE FOR 4.5 CORTEX SCREW.; SCRDRIVER STARDRIVE T25 SELF-HOLDING L 2.; SELDRILL-SCHANZSCR Ø5 L175/60 SST.
Patient SexUnknown
-
-