| Catalog Number |
4A5044 |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Codes |
Urinary Tract Infection (2120); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
01/15/2026
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The investigation is still in progress.Once the investigation is complete, a supplemental report will be filed.Udi format updated with available product information per gudid.H11: sections a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported that the customer had been using the 4a2045 kit successfully for an extended period and experienced no issues with leakage or infections.Since this product was discontinued, customers have been using the suggested replacement, sku 4a5044, which was a unisex catheter kit.Customer reports that this alternative does not work well for them, noting that it consistently leaks and does not function in the same way as the male specific design.Customer also shared that they have trialed multiple substitute products over the past few months, and all have resulted in utis and additional difficulties, making the discontinued 4a2045 the only product that reliably met their clinical needs.It was unknown what medical intervention was provided for urinary tract infection.
|
| |
|
Event or Problem Description
|
|
It was reported that the customer had been using the 4a2045 kit successfully for an extended period and experienced no issues with leakage or infections.Since this product was discontinued, customers have been using the suggested replacement, sku 4a5044, which was a unisex catheter kit.Customer reports that this alternative does not work well for them, noting that it consistently leaks and does not function in the same way as the male specific design.Customer also shared that they have trialed multiple substitute products over the past few months, and all have resulted in utis and additional difficulties, making the discontinued 4a2045 the only product that reliably met their clinical needs.It was unknown what medical intervention was provided for urinary tract infection.
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event was inconclusive because this investigation did not result in any additional findings and no sample was available for evaluation.The reported event is addressed within the labeling as it states:
instructions for use:
preparing for catheterization:
1.Open kit and remove contents.2.The gloves are not necessary to maintain aseptic conditions during the procedure.The gloves are for the operator's protection.Male or female catheterization:
1.Remove cap from insertion tip while squeezing tabs.Save cap for closing the bag.2.Slide the catheter halfway into the insertion tip.3.Male prepare the male urethral meatus and the surrounding area with povidone iodine swabs provided.4.Male holding the penis, advance the insertion tip into the urethra no further than the flange base.5.Place your nondominant hand on the finger control guide to stabilize catheter in urethra.With your dominant hand, grasp catheter through bag approximately 1in below the finger control guide and push catheter into urethra.The catheter should be introduced by short, repetitive pushing motions.Repeat motions until catheter reaches bladder and urine starts to flow.6.Allow urine to flow freely, making certain the catheter guide is elevated at least 4in above lower portion of the bag.Allow flow until bladder is empty or until bag is filled.Precaution: it is recommended that the collection bag be held.The catheter could possibly separate from the collection bag when urine increases weight of the bag.7.Withdraw the catheter from the urethra.Remove the remaining portion of the catheter from the collection bag by pulling it through the insertion tip.Note: the catheter is designed to pass through the insertion tip.8.The filled collection bag may be closed by replacing the cap over the insertion tip.Make sure the cap snaps on securely.Specimen collection:
to collect a specimen, obtain a sample cup or tube and alcohol wipe.Remove guide tip by pulling tab(s) upward from bag.Wipe port with alcohol.Pour specimen through port at top of bag into cup or tube.Draining bag:
remove insertion tip by pulling tab(s) upward from bag.Drain urine through port at top of bag.The dhr review could not be performed without a lot number.No additional actions can be taken at this time.Correction: d.Udi format updated with available product information per gudid.H11: sections a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|