• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION AMS 700 CX MS PUMP; PROSTHESIS, PENIS, INFLATABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION AMS 700 CX MS PUMP; PROSTHESIS, PENIS, INFLATABLE Back to Search Results
Model Number 72404233
Medical Device Problem Codes Nonstandard Device (1420); Material Puncture/Hole (1504)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/07/2026
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The device is not available for analysis; therefore, no physical analysis of the product could be performed.The reported device performance allegation cannot be confirmed.Based on the information available the cause that contributed to the reported event cannot be established.
 
Event or Problem Description
It was reported that the cylinder of this inflatable penile prosthesis (ipp) was ruptured.As a result, the cylinders and pump were explanted and replaced.No additional information reported.
 
Event or Problem Description
It was reported that the cylinder of this inflatable penile prosthesis (ipp) was ruptured.As a result, the cylinders and pump were explanted and replaced.No additional information reported.
 
Event or Problem Description
It was reported that the cylinder of this inflatable penile prosthesis (ipp) was ruptured.As a result, the cylinders and pump were explanted and replaced.No additional information reported.
 
Additional Manufacturer Narrative
Correction to field b1: adverse event/product problem.Upon receipt at our quality assurance laboratory, this inflatable penile prosthesis (ipp) underwent a thorough analysis.The pump was microscopically inspected, functionally and leak tested.Under microscope observation, contamination (bodily fluid) was found within the ms pump.As a result, the functional test was not performed.No leaks were identified.The cylinders were microscopically inspected, and leak tested.The microscope test found that the first cylinder had a had broken fabric threads from wear in the proximal end to the middle of the cylinder.The second cylinder had wear at fold in the proximal end of the cylinder.Both cylinders had a hole in the outer tube and broken fabric threads from kink resistant tubing (krt) wear in the proximal end of the cylinder and the krt was worn to the filament.Both cylinders did not pass the leak test.The device history record (dhr) review confirmed that the device met all material, assembly and performance specifications.A review of the device instructions for use (ifu) was completed and did not reveal any evidence of device misuse, off label use, or failure to follow instructions.A risk review was completed and confirmed that the events of mechanical malfunction (leaks, incomplete inflation/ deflation, kinking) and device has a fluid leak were defined in the product risk documentation.This event type has been accounted for during analysis to support acceptable risk benefit for the product.Based on the available information and analysis results, the leaks in both cylinders from krt, supports the reported clinical observation of cylinder hole/perforation.Therefore, a conclusion code of cause traced to component failure was assigned to this investigation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AMS 700 CX MS PUMP
Common Device Name
PROSTHESIS, PENIS, INFLATABLE
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer Contact
farshad fahimi
4100 hamline avenue north
building c
saint paul, MN 55112
MDR Report Key24217837
Report Number2124215-2026-05396
Device Sequence Number20882113
Product Code JCW
Combination Product (Y/N)Y
Initial Reporter CountryIT
PMA/510(K) Number
N970012
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Device Explanted Year2026
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 06/18/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date01/05/2018
Device Model Number72404233
Device Catalogue Number72404233
Device Lot Number114758005
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/14/2026
Supplement Date Received by Manufacturer04/10/2026
05/22/2026
Initial Report FDA Received Date01/29/2026
Supplement Report FDA Received Date04/29/2026
06/19/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/21/2016
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient SexUnknown
-
-