| Model Number |
72404233 |
| Medical Device Problem Codes |
Nonstandard Device (1420); Material Puncture/Hole (1504)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/07/2026
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The device is not available for analysis; therefore, no physical analysis of the product could be performed.The reported device performance allegation cannot be confirmed.Based on the information available the cause that contributed to the reported event cannot be established.
|
| |
|
Event or Problem Description
|
|
It was reported that the cylinder of this inflatable penile prosthesis (ipp) was ruptured.As a result, the cylinders and pump were explanted and replaced.No additional information reported.
|
| |
|
Event or Problem Description
|
|
It was reported that the cylinder of this inflatable penile prosthesis (ipp) was ruptured.As a result, the cylinders and pump were explanted and replaced.No additional information reported.
|
| |
|
Event or Problem Description
|
|
It was reported that the cylinder of this inflatable penile prosthesis (ipp) was ruptured.As a result, the cylinders and pump were explanted and replaced.No additional information reported.
|
| |
|
Additional Manufacturer Narrative
|
|
Correction to field b1: adverse event/product problem.Upon receipt at our quality assurance laboratory, this inflatable penile prosthesis (ipp) underwent a thorough analysis.The pump was microscopically inspected, functionally and leak tested.Under microscope observation, contamination (bodily fluid) was found within the ms pump.As a result, the functional test was not performed.No leaks were identified.The cylinders were microscopically inspected, and leak tested.The microscope test found that the first cylinder had a had broken fabric threads from wear in the proximal end to the middle of the cylinder.The second cylinder had wear at fold in the proximal end of the cylinder.Both cylinders had a hole in the outer tube and broken fabric threads from kink resistant tubing (krt) wear in the proximal end of the cylinder and the krt was worn to the filament.Both cylinders did not pass the leak test.The device history record (dhr) review confirmed that the device met all material, assembly and performance specifications.A review of the device instructions for use (ifu) was completed and did not reveal any evidence of device misuse, off label use, or failure to follow instructions.A risk review was completed and confirmed that the events of mechanical malfunction (leaks, incomplete inflation/ deflation, kinking) and device has a fluid leak were defined in the product risk documentation.This event type has been accounted for during analysis to support acceptable risk benefit for the product.Based on the available information and analysis results, the leaks in both cylinders from krt, supports the reported clinical observation of cylinder hole/perforation.Therefore, a conclusion code of cause traced to component failure was assigned to this investigation.
|
| |
|