• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: FRESENIUS VIAL S.A.S. VOLUMAT MC AGILIA US; INFUSION PUMP SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

FRESENIUS VIAL S.A.S. VOLUMAT MC AGILIA US; INFUSION PUMP SYSTEM Back to Search Results
Model Number Z021135
Medical Device Problem Codes Excess Flow or Over-Infusion (1311); No Apparent Adverse Event (3189)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/19/2026
Type of Reportable Event Malfunction
Event or Problem Description
The following has been reported by customer: pump infused medication at fast rate.Customer emailed in the request form reporting: pump infused medication at rate faster than it was programmed for.Reporting as a conservative measure.Adverse effects were not reported.Additional information is needed to complete the investigation.
 
Event or Problem Description
Device history record was reviewed.No event linked with the reported issue was observed.Device log was reviewed, no error or issue linked to the reported event was found.The reported device was received in lake zurich and its investigation was performed by our local technical team.According to provided information, nothing was noticed during both external and internal check (except the externals, internals and inseams found dirty).Several functional tests related to the reported event were carried out.All performed successfully and values were found compliant with ifu specifications compared to settings.The reported event could not be reproduced.Based on available information, this complaint is considered as not valid with no issue.To our knowledge this complaint is not being related to patient safety.This complaint is considered as: not valid.The trend is: n/a.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VOLUMAT MC AGILIA US
Common Device Name
INFUSION PUMP SYSTEM
Manufacturer (Section D)
FRESENIUS VIAL S.A.S.
le grand chemin
brezins, 38590
FR  38590
Manufacturer (Section G)
FRESENIUS VIAL S.A.S.
le grand chemin
brezins, 38590
FR   38590
Manufacturer Contact
rebecca mccandless
3 corporate drive
lake zurich, IL 60047
8475502913
MDR Report Key24220856
Report Number3000240707-2026-00023
Device Sequence Number8196899
Product Code FRN
UDI-Device Identifier04086000851794
UDI-Public04086000851794
Combination Product (Y/N)N
Initial Reporter StateTN
Initial Reporter CountryUS
PMA/510(K) Number
K121613
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 02/17/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Model NumberZ021135
Device Catalogue NumberZ021135
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/19/2026
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date01/30/2026
Supplement Report FDA Received Date02/17/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured11/07/2017
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-