• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC SOFAMOR DANEK USA, INC. KYPHON® XPEDE¿ BONE CEMENT; CEMENT, BONE, VERTEBROPLASTY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC SOFAMOR DANEK USA, INC. KYPHON® XPEDE¿ BONE CEMENT; CEMENT, BONE, VERTEBROPLASTY Back to Search Results
Model Number CX01A
Medical Device Problem Codes Coagulation in Device or Device Ingredient (1096); Product Quality Problem (1506)
Health Effect - Clinical Code Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 01/06/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
H6: neither the device nor films of applicable imaging studies were returned to the manufacturer for evaluation.Therefore, we are unable to determine the definitive cause of the reported event.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Event or Problem Description
Information was received from an healthcare provider (hcp) via manufacture representative regarding a product used in osteocool spinal therapy for thoracic pain, metastasis to vertebral body at level t11.It was reported that during an osteocool case involving mixer and cement, surgeon experienced significant difficulty mixing the bone cement despite following proper technique and labeling instructions.The cement did not achieve the normal smooth consistency, and large chunks of powdered cement were observed stuck to the mixer.After the initial mixing, only 1-2 cc of cement could be extruded into cartridges before it became very difficult to push out anymore.Both were unable to push more than 1 cc of cement into the egg, and two sets of previously mixed cement were discarded by the facility.The issue was resolved by assembling a new cement kit and using the included syringe and needle to draw up the liquid component, which resulted in easier mixing and the correct consistency.The cement was then successfully delivered via cds gun and bone filler without further issue.There were no further complications or symptoms reported regarding the event.Additional information was received via manufacturer representative that procedure was completed successfully but patient did not experience significant pain relief from procedure.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
KYPHON® XPEDE¿ BONE CEMENT
Common Device Name
CEMENT, BONE, VERTEBROPLASTY
Manufacturer (Section D)
MEDTRONIC SOFAMOR DANEK USA, INC.
4340 swinea rd
memphis TN 38118
Manufacturer (Section G)
MEDTRONIC SOFAMOR DANEK USA, INC.
4340 swinea rd
memphis TN 38118
Manufacturer Contact
justin ellis
1800 pyramid place
memphis, TN 38132
7635265677
MDR Report Key24243484
Report Number3003120897-2026-00165
Device Sequence Number9618731
Product Code NDN
UDI-Device Identifier00643169097803
UDI-Public(01)00643169097803(17)280630(10)EL70370
Combination Product (Y/N)N
Initial Reporter StateID
Initial Reporter CountryUS
PMA/510(K) Number
K102397
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 02/03/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberCX01A
Device Catalogue NumberCX01A
Device Lot NumberEL70370
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/06/2026
Initial Report FDA Received Date02/03/2026
Date Device Manufactured09/02/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-