| Model Number |
N/A |
| Medical Device Problem Codes |
Product Quality Problem (1506); Material Twisted/Bent (2981)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/15/2026
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported 19 g needle (0.75 in) was inserted for transfusion of prbc.Brisk blood returned noted and patient denied no discomfort.Patient tolerated transfusion well.Writer was unable to retract port-a-cath needle at the end of transfusion.Flushed well with no concerns.No success after changing position.Port-a-cath needle removed as is after different attempts from 4 different nurses.Patient denied discomfort.Prolonged patient care, but no serious harm reported.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The manufacturer has received the sample and will be evaluated.A supplemental will be submitted with evaluation results.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The complaint of bent needle was confirmed and the cause was determined to be use related.The product returned for evaluation was a 19 ga x 0.75 in safestep infusion set.The returned product sample was evaluated and the needle was observed to be bent near its base.The following observations were noted during the sample evaluation: ¿ usage residue was seen on the sample which proved that the product had experienced at least some use.¿ the needle tip was barbed suggesting contact between the needle and port base.An attempt to advance the safety over the needle tip was unsuccessful as the safety could not pass the bent region of the needle.Force applied at an angle to the needle axis, or if the needle is not inserted perpendicular into the port septum, can lead to bending of the needle shaft.It is advised to verify that the needle length is correct based on port reservoir depth, tissue thickness and the thickness of any dressing beneath the bend of the needle; if too long, needle and/or port may be damaged at insertion.Additionally, avoid excessive manipulation once the needle is in the port.No potential damage related to the manufacturing process was noted on the complaint sample.This complaint will be recorded for future trending and monitoring purposes.
|
| |
|
Search Alerts/Recalls
|