Product complaint #(b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.A manufacturing record evaluation was performed for the finished device lot, and no non-conformances were identified.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.The photo provided shows ethicon suture packaging for: 770g ¿ plain gut suture g121 ¿ chromic gut suture the complaint was initially created for product code 770g ¿ plain gut.In addition to product code 770g ¿ plain gut, was product code g121 ¿ chromic gut also used on the patient? if yes, please provide the lot number of the g121 ¿ chromic gut suture.Please provide the patient's demographic information including age, gender, weight, bmi at the time of index procedure.Date of index surgical procedure? were any concomitant procedures performed? on what tissue was the suture used? what was the tissue condition (normal, thin, calcified, fragile, diseased)? for the original intended closure, how were all layers closed? how was the suture placed (interrupted or continuous)? were any non-ethicon sutures used during the procedure? if yes, please provide name.Please describe the patient manifestations of the reported infection (location, severity, appearance).Please provide the onset date/time of infection from the initial surgical procedure.Were there any pre-existing signs/symptoms of active infection prior to this surgical procedure? did the patient receive any prophylactic antibiotics pre-, intra- or post-operation? were cultures and sensitivities performed? if so, please provide the results.Was the patient recently exposed to any farm animals? how much and what type of drainage is present in this wound? please describe any medical intervention performed including medication name and results.Were any pre-op cleansing procedures changed recently? if yes, please describe did the operating surgeon observe any suture deficiency or anomaly before, during, after the suture placement or during any re-operation? other relevant patient history/concomitant medications? what is the physician¿s opinion as to the etiology of or contributing factors to this event? what is the patient's current status? surgeon¿s name? will product be returned? if so, please provide the return date and tracking information.H6 investigation findings: c22 - photo review h3 investigation summary: this is an analysis for a photo submitted to ethicon for evaluation.During the visual analysis, the following was observed: the photo shows three packages with different codes; the reported closed package is labeled with product code 770g, lot number tcmcqm.The image is not clear to determine the failure mode or the reported condition.Based on the photo review, the event reported is not confirmed, however no conclusion or root cause could be determined.Hands on device analysis may provide the additional evidence necessary to confirm the root cause of the reported event.Because the device was not returned our evaluation is limited.We value the opportunity to fully analyze the device upon its return.As part of ethicon quality process all devices are manufactured, inspected, and released to approved specifications.Additional complaint information monitoring for potential safety signals will be conducted through complaint trending as part of post market surveillance.
|