BOSTON SCIENTIFIC CORPORATION OBTRYX II SYSTEM - CURVED; MESH, SURGICAL, SYNTHETIC, UROGYNECOLOGIC, FOR STRESS URINARY INCONTINENCE, RETR
|
Back to Search Results |
|
| Model Number |
M0068504110 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Abdominal Pain (1685); Fall (1848); Unspecified Infection (1930); Inflammation (1932); Nausea (1970); Necrosis (1971); Pain (1994); Vomiting (2144); Electrolyte Imbalance (2196); Obstruction/Occlusion (2422); Prolapse (2475); Constipation (3274); Unspecified Mental, Emotional or Behavioural Problem (4430); Unspecified Kidney or Urinary Problem (4503); Unspecified Tissue Injury (4559); Insufficient Information (4580); High White Blood Cell Count (4594)
|
| Date of Event |
06/19/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Block b3 date of event: the exact event onset date is unknown.The provided event date of june 19, 2023, was chosen as a best estimate based on the date of mesh implant.Block e1: this event was reported by the patient's legal representation.The implanting physician is: dr.(b)(6) (b)(6) hospital (b)(6) united states (b)(6) phone: (b)(6) block h6: the following imdrf patient codes capture the reportable events of: e2328 - bowel obstruciton.E2327 - necrosis.E2326 - inflammation.E1906 - infection.E2330 - pain.E1002 - abdominal pain.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient was implanted with an obtryx - curve and upsylon y-mesh for the treatment of prolapse and stress urinary incontinence on a transobturator tape sling procedure performed on (b)(6) 2023.During the same procedure, perineorrhaphy and cystoscopy were also performed.On (b)(6) 2024, sigmoid colon pathology was performed and demonstrated no significant abnormality, with multiple deeper tissue levels examined.On (b)(6) 2024, atypical squamous cells of undetermined significance was identified.On (b)(6) 2025, the patient underwent bilateral screening mammography, which revealed asymmetry in the left breast with equivocal distortion and an adjacent potential mass.A left 3-d mammogram and ultrasound were recommended for further evaluation, while the right breast mammogram was negative.Additional imaging findings classified the breast tissue as density category b, with scattered fibroglandular density.The asymmetry with equivocal distortion was noted in the middle to posterior third of the left outer breast, likely corresponding superiorly on the mediolateral oblique (mlo) view, and a 5-mm potential mass was identified lateral and superior to the asymmetry.On (b)(6) 2025, the patient underwent a targeted left breast ultrasound, which demonstrated resolution of the previously noted asymmetry.The finding was determined to be consistent with overlapping fibroglandular tissue, and the ultrasound was negative for suspicious abnormalities.The breasts remained classified as density category b, and the imaging appearance was consistent with prior studies.No breast physical examination was performed.Annual screening mammography with tomosynthesis was recommended.On september 9, 2025, the patient presented with lower back pain radiating to the lower back, accompanied by nausea and vomiting, with symptom onset at approximately 10:30 p.M.An abdominal computed tomography (ct) scan was performed and showed no radiographic evidence to explain the reported symptoms.On (b)(6) 2025, an abdominal x-ray was obtained; however, the abdomen was not fully imaged.The enteric tube remained similarly positioned, with the tip projecting over the mid-stomach.Gas-dilated small bowel loops were observed in the right hemiabdomen, measuring up to 4.1 cm in diameter, which could have represented ileus or small bowel obstruction.Additional imaging showed the tip of a new enteric tube positioned within the expected location of the gastric body, with the sidehole at the level of the diaphragm.Mildly to moderately dilated, air-filled small bowel loops were noted on the right side of the abdomen, which could have been related to ileus or obstruction.Short-term follow-up imaging was recommended.A mildly dilated small bowel loop in the mid-abdomen measuring up to 3.4 cm was also identified, potentially consistent with focal ileus or early/partial small bowel obstruction.On (b)(6) 2025, a repeat abdominal x-ray demonstrated no significant interval change in small bowel dilation, with a similar position of enteric contrast.The enteric tube tip remained positioned within the gastric body, with contrast visible in the distended stomach.Additional contrast was present within some dilated small bowel loops, and the caliber of the dilated loops appeared mildly reduced, possibly reflecting interval improvement in small bowel obstruction versus ileus.No contrast was identified within the colon.On (b)(6) 2025, the patient underwent an abdominal x-ray, which demonstrated that the nasogastric (ng) tube tip was positioned within the mid-stomach.Gastrografin contrast had progressed into the proximal small bowel loops, and there was persistent mild distention of the small bowel, with gas present in the right colon.On (b)(6) 2025, an abdominal computed tomography (ct) scan was performed due to concern for small bowel obstruction (sbo) with failure of a gastrografin challenge.Imaging revealed interval development of a segment of dilated small bowel in the pelvis with two transition points, raising concern for a closed-loop obstruction, potentially volvulus.Gas noted along the anterior aspect of the dilated bowel loop may have represented intraluminal gas or evolving ischemia.A surrounding fluid collection with enhancement of the bowel wall and peritoneum was observed, which could have been reactive or suggestive of infection, and surgical evaluation was recommended.Additional findings included mild bladder wall thickening and perivesical stranding, possibly reactive to adjacent bowel inflammation or consistent with cystitis, as well as a small pericardial effusion and cholelithiasis.Further ct findings included a small pericardial effusion in the lower thorax without evidence of acute airspace disease.The liver exhibited noncirrhotic morphology with stable central hepatic cysts and additional subcentimeter low-attenuation lesions, likely representing cysts or hemangiomas.Cholelithiasis was present without evidence of cholecystitis or biliary ductal dilation.The pancreas appeared normal, with no focal masses or ductal dilation.The spleen was normal in size, and no adrenal nodules were identified.The kidneys and ureters showed no hydronephrosis, calculi, or solid masses.The urinary bladder demonstrated mild wall thickening and perivesical stranding.The rectum and distal small bowel were decompressed, with rectal wall thickening noted, likely reactive.No lymphadenopathy was observed.The abdominal aorta and major venous structures, including the hepatic, portal, splenic, and superior mesenteric veins, were patent and normal in caliber.No acute or aggressive osseous abnormalities were identified, although mild multilevel degenerative disc disease was present.Later on (b)(6) 2025, an abdominal x-ray demonstrated that the enteric tube was in place, with the sidehole positioned at the gastroesophageal (ge) junction and the tip in the proximal stomach.Advancement of approximately 5 cm was recommended to optimize positioning.Multiple dilated small bowel loops were again observed, partially opacified with contrast, consistent with obstruction previously identified on ct.On (b)(6) 2025, surgical pathology evaluation identified a segment of small bowel with transmural ischemic necrosis.On (b)(6) 2026, the patient presented for clinical evaluation related to attention and concentration deficits.Note: this manufacturer report pertains to the first of two devices implanted in the same procedure.
|
| |
|
Additional Manufacturer Narrative
|
|
Block h11: with all the available information, boston scientific concludes that the reported adverse events of bowel obstruction, necrosis, inflammation, injury, nos (not otherwise specified), cholecystitis, infection, unspecified kidney or urinary problem, pain, abdominal pain, vomiting, nausea, constipation, prolapse, fall, unspecified mental, emotional or behavioural problem, high white blood cell count, and electrolyte imbalance are known risks of the surgical procedure.The device is not available for analysis; therefore, no physical or visual analysis of the product could be performed.There was no report of a device performance allegation.The reported patient symptoms are known risks associated with this device type and indicated as such in the instructions for use.The device history record (dhr) confirmed that the device met all material, assembly, and performance specifications.The investigation concluded that the most probable cause for this event is known inherent risk of device, which indicates that the reported adverse event is known and documented in the labeling (including both short or long term known complications or adverse reactions).Block b3 date of event: the exact event onset date is unknown.The provided event date of june 19, 2023, was chosen as a best estimate based on the date of mesh implant.(b)(6).Block h6: the following imdrf patient codes capture the reportable events of: e2328 - bowel obstruciton, e2327 - necrosis, e2326 - inflammation, e1906 - infection, e2330 - pain, e1002 - abdominal pain.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient was implanted with an obtryx - curve and upsylon y-mesh for the treatment of prolapse and stress urinary incontinence on a transobturator tape sling procedure performed on (b)(6) 2023.During the same procedure, perineorrhaphy and cystoscopy were also performed.On (b)(6) 2024, sigmoid colon pathology was performed and demonstrated no significant abnormality, with multiple deeper tissue levels examined.On (b)(6) 2024, atypical squamous cells of undetermined significance was identified.On (b)(6) 2025, the patient underwent bilateral screening mammography, which revealed asymmetry in the left breast with equivocal distortion and an adjacent potential mass.A left 3-d mammogram and ultrasound were recommended for further evaluation, while the right breast mammogram was negative.Additional imaging findings classified the breast tissue as density category b, with scattered fibroglandular density.The asymmetry with equivocal distortion was noted in the middle to posterior third of the left outer breast, likely corresponding superiorly on the mediolateral oblique (mlo) view, and a 5-mm potential mass was identified lateral and superior to the asymmetry.On (b)(6) 2025, the patient underwent a targeted left breast ultrasound, which demonstrated resolution of the previously noted asymmetry.The finding was determined to be consistent with overlapping fibroglandular tissue, and the ultrasound was negative for suspicious abnormalities.The breasts remained classified as density category b, and the imaging appearance was consistent with prior studies.No breast physical examination was performed.Annual screening mammography with tomosynthesis was recommended.On (b)(6) 2025, the patient presented with lower back pain radiating to the lower back, accompanied by nausea and vomiting, with symptom onset at approximately 10:30 p.M.An abdominal computed tomography (ct) scan was performed and showed no radiographic evidence to explain the reported symptoms.On (b)(6) 2025, an abdominal x-ray was obtained; however, the abdomen was not fully imaged.The enteric tube remained similarly positioned, with the tip projecting over the mid-stomach.Gas-dilated small bowel loops were observed in the right hemiabdomen, measuring up to 4.1 cm in diameter, which could have represented ileus or small bowel obstruction.Additional imaging showed the tip of a new enteric tube positioned within the expected location of the gastric body, with the sidehole at the level of the diaphragm.Mildly to moderately dilated, air-filled small bowel loops were noted on the right side of the abdomen, which could have been related to ileus or obstruction.Short-term follow-up imaging was recommended.A mildly dilated small bowel loop in the mid-abdomen measuring up to 3.4 cm was also identified, potentially consistent with focal ileus or early/partial small bowel obstruction.On (b)(6) 2025, a repeat abdominal x-ray demonstrated no significant interval change in small bowel dilation, with a similar position of enteric contrast.The enteric tube tip remained positioned within the gastric body, with contrast visible in the distended stomach.Additional contrast was present within some dilated small bowel loops, and the caliber of the dilated loops appeared mildly reduced, possibly reflecting interval improvement in small bowel obstruction versus ileus.No contrast was identified within the colon.On (b)(6) 2025, the patient underwent an abdominal x-ray, which demonstrated that the nasogastric (ng) tube tip was positioned within the mid-stomach.Gastrografin contrast had progressed into the proximal small bowel loops, and there was persistent mild distention of the small bowel, with gas present in the right colon.On (b)(6) 2025, an abdominal computed tomography (ct) scan was performed due to concern for small bowel obstruction (sbo) with failure of a gastrografin challenge.Imaging revealed interval development of a segment of dilated small bowel in the pelvis with two transition points, raising concern for a closed-loop obstruction, potentially volvulus.Gas noted along the anterior aspect of the dilated bowel loop may have represented intraluminal gas or evolving ischemia.A surrounding fluid collection with enhancement of the bowel wall and peritoneum was observed, which could have been reactive or suggestive of infection, and surgical evaluation was recommended.Additional findings included mild bladder wall thickening and perivesical stranding, possibly reactive to adjacent bowel inflammation or consistent with cystitis, as well as a small pericardial effusion and cholelithiasis.Further ct findings included a small pericardial effusion in the lower thorax without evidence of acute airspace disease.The liver exhibited noncirrhotic morphology with stable central hepatic cysts and additional subcentimeter low-attenuation lesions, likely representing cysts or hemangiomas.Cholelithiasis was present without evidence of cholecystitis or biliary ductal dilation.The pancreas appeared normal, with no focal masses or ductal dilation.The spleen was normal in size, and no adrenal nodules were identified.The kidneys and ureters showed no hydronephrosis, calculi, or solid masses.The urinary bladder demonstrated mild wall thickening and perivesical stranding.The rectum and distal small bowel were decompressed, with rectal wall thickening noted, likely reactive.No lymphadenopathy was observed.The abdominal aorta and major venous structures, including the hepatic, portal, splenic, and superior mesenteric veins, were patent and normal in caliber.No acute or aggressive osseous abnormalities were identified, although mild multilevel degenerative disc disease was present.Later on (b)(6) 2025, an abdominal x-ray demonstrated that the enteric tube was in place, with the sidehole positioned at the gastroesophageal (ge) junction and the tip in the proximal stomach.Advancement of approximately 5 cm was recommended to optimize positioning.Multiple dilated small bowel loops were again observed, partially opacified with contrast, consistent with obstruction previously identified on ct.On (b)(6) 2025, surgical pathology evaluation identified a segment of small bowel with transmural ischemic necrosis.On (b)(6) 2026, the patient presented for clinical evaluation related to attention and concentration deficits.Note: this manufacturer report pertains to the first of two devices implanted in the same procedure.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient was implanted with an obtryx - curve and upsylon y-mesh for the treatment of prolapse and stress urinary incontinence on a transobturator tape sling procedure performed on (b)(6) 2023.During the same procedure, perineorrhaphy and cystoscopy were also performed.On (b)(6) 2024, sigmoid colon pathology was performed and demonstrated no significant abnormality, with multiple deeper tissue levels examined.On (b)(6) 2024, atypical squamous cells of undetermined significance was identified.On (b)(6) 2025, the patient underwent bilateral screening mammography, which revealed asymmetry in the left breast with equivocal distortion and an adjacent potential mass.A left 3-d mammogram and ultrasound were recommended for further evaluation, while the right breast mammogram was negative.Additional imaging findings classified the breast tissue as density category b, with scattered fibroglandular density.The asymmetry with equivocal distortion was noted in the middle to posterior third of the left outer breast, likely corresponding superiorly on the mediolateral oblique (mlo) view, and a 5-mm potential mass was identified lateral and superior to the asymmetry.On (b)(6) 2025, the patient underwent a targeted left breast ultrasound, which demonstrated resolution of the previously noted asymmetry.The finding was determined to be consistent with overlapping fibroglandular tissue, and the ultrasound was negative for suspicious abnormalities.The breasts remained classified as density category b, and the imaging appearance was consistent with prior studies.No breast physical examination was performed.Annual screening mammography with tomosynthesis was recommended.On (b)(6) 2025, the patient presented with lower back pain radiating to the lower back, accompanied by nausea and vomiting, with symptom onset at approximately 10:30 p.M.An abdominal computed tomography (ct) scan was performed and showed no radiographic evidence to explain the reported symptoms.On (b)(6) 2025, an abdominal x-ray was obtained; however, the abdomen was not fully imaged.The enteric tube remained similarly positioned, with the tip projecting over the mid-stomach.Gas-dilated small bowel loops were observed in the right hemiabdomen, measuring up to 4.1 cm in diameter, which could have represented ileus or small bowel obstruction.Additional imaging showed the tip of a new enteric tube positioned within the expected location of the gastric body, with the sidehole at the level of the diaphragm.Mildly to moderately dilated, air-filled small bowel loops were noted on the right side of the abdomen, which could have been related to ileus or obstruction.Short-term follow-up imaging was recommended.A mildly dilated small bowel loop in the mid-abdomen measuring up to 3.4 cm was also identified, potentially consistent with focal ileus or early/partial small bowel obstruction.On (b)(6) 2025, a repeat abdominal x-ray demonstrated no significant interval change in small bowel dilation, with a similar position of enteric contrast.The enteric tube tip remained positioned within the gastric body, with contrast visible in the distended stomach.Additional contrast was present within some dilated small bowel loops, and the caliber of the dilated loops appeared mildly reduced, possibly reflecting interval improvement in small bowel obstruction versus ileus.No contrast was identified within the colon.On (b)(6) 2025, the patient underwent an abdominal x-ray, which demonstrated that the nasogastric (ng) tube tip was positioned within the mid-stomach.Gastrografin contrast had progressed into the proximal small bowel loops, and there was persistent mild distention of the small bowel, with gas present in the right colon.On (b)(6) 2025, an abdominal computed tomography (ct) scan was performed due to concern for small bowel obstruction (sbo) with failure of a gastrografin challenge.Imaging revealed interval development of a segment of dilated small bowel in the pelvis with two transition points, raising concern for a closed-loop obstruction, potentially volvulus.Gas noted along the anterior aspect of the dilated bowel loop may have represented intraluminal gas or evolving ischemia.A surrounding fluid collection with enhancement of the bowel wall and peritoneum was observed, which could have been reactive or suggestive of infection, and surgical evaluation was recommended.Additional findings included mild bladder wall thickening and perivesical stranding, possibly reactive to adjacent bowel inflammation or consistent with cystitis, as well as a small pericardial effusion and cholelithiasis.Further ct findings included a small pericardial effusion in the lower thorax without evidence of acute airspace disease.The liver exhibited noncirrhotic morphology with stable central hepatic cysts and additional subcentimeter low-attenuation lesions, likely representing cysts or hemangiomas.Cholelithiasis was present without evidence of cholecystitis or biliary ductal dilation.The pancreas appeared normal, with no focal masses or ductal dilation.The spleen was normal in size, and no adrenal nodules were identified.The kidneys and ureters showed no hydronephrosis, calculi, or solid masses.The urinary bladder demonstrated mild wall thickening and perivesical stranding.The rectum and distal small bowel were decompressed, with rectal wall thickening noted, likely reactive.No lymphadenopathy was observed.The abdominal aorta and major venous structures, including the hepatic, portal, splenic, and superior mesenteric veins, were patent and normal in caliber.No acute or aggressive osseous abnormalities were identified, although mild multilevel degenerative disc disease was present.Later on (b)(6) 2025, an abdominal x-ray demonstrated that the enteric tube was in place, with the sidehole positioned at the gastroesophageal (ge) junction and the tip in the proximal stomach.Advancement of approximately 5 cm was recommended to optimize positioning.Multiple dilated small bowel loops were again observed, partially opacified with contrast, consistent with obstruction previously identified on ct.On (b)(6) 2025, surgical pathology evaluation identified a segment of small bowel with transmural ischemic necrosis.On (b)(6) 2026, the patient presented for clinical evaluation related to attention and concentration deficits.Note: this manufacturer report pertains to the first of two devices implanted in the same procedure.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient was implanted with an obtryx - curve and upsylon y-mesh for the treatment of prolapse and stress urinary incontinence on a transobturator tape sling procedure performed on (b)(6) 2023.During the same procedure, perineorrhaphy and cystoscopy were also performed.On (b)(6) 2024, sigmoid colon pathology was performed and demonstrated no significant abnormality, with multiple deeper tissue levels examined.On (b)(6)2024, atypical squamous cells of undetermined significance was identified.On (b)(6) 2025, the patient underwent bilateral screening mammography, which revealed asymmetry in the left breast with equivocal distortion and an adjacent potential mass.A left 3-d mammogram and ultrasound were recommended for further evaluation, while the right breast mammogram was negative.Additional imaging findings classified the breast tissue as density category b, with scattered fibroglandular density.The asymmetry with equivocal distortion was noted in the middle to posterior third of the left outer breast, likely corresponding superiorly on the mediolateral oblique (mlo) view, and a 5-mm potential mass was identified lateral and superior to the asymmetry.On (b)(6) 2025, the patient underwent a targeted left breast ultrasound, which demonstrated resolution of the previously noted asymmetry.The finding was determined to be consistent with overlapping fibroglandular tissue, and the ultrasound was negative for suspicious abnormalities.The breasts remained classified as density category b, and the imaging appearance was consistent with prior studies.No breast physical examination was performed.Annual screening mammography with tomosynthesis was recommended.On (b)(6) 2025, the patient presented with lower back pain radiating to the lower back, accompanied by nausea and vomiting, with symptom onset at approximately 10:30 p.M.An abdominal computed tomography (ct) scan was performed and showed no radiographic evidence to explain the reported symptoms.On (b)(6) 2025, an abdominal x-ray was obtained; however, the abdomen was not fully imaged.The enteric tube remained similarly positioned, with the tip projecting over the mid-stomach.Gas-dilated small bowel loops were observed in the right hemiabdomen, measuring up to 4.1 cm in diameter, which could have represented ileus or small bowel obstruction.Additional imaging showed the tip of a new enteric tube positioned within the expected location of the gastric body, with the sidehole at the level of the diaphragm.Mildly to moderately dilated, air-filled small bowel loops were noted on the right side of the abdomen, which could have been related to ileus or obstruction.Short-term follow-up imaging was recommended.A mildly dilated small bowel loop in the mid-abdomen measuring up to 3.4 cm was also identified, potentially consistent with focal ileus or early/partial small bowel obstruction.On (b)(6) 2025, a repeat abdominal x-ray demonstrated no significant interval change in small bowel dilation, with a similar position of enteric contrast.The enteric tube tip remained positioned within the gastric body, with contrast visible in the distended stomach.Additional contrast was present within some dilated small bowel loops, and the caliber of the dilated loops appeared mildly reduced, possibly reflecting interval improvement in small bowel obstruction versus ileus.No contrast was identified within the colon.On (b)(6) 2025, the patient underwent an abdominal x-ray, which demonstrated that the nasogastric (ng) tube tip was positioned within the mid-stomach.Gastrografin contrast had progressed into the proximal small bowel loops, and there was persistent mild distention of the small bowel, with gas present in the right colon.On (b)(6) 2025, an abdominal computed tomography (ct) scan was performed due to concern for small bowel obstruction (sbo) with failure of a gastrografin challenge.Imaging revealed interval development of a segment of dilated small bowel in the pelvis with two transition points, raising concern for a closed-loop obstruction, potentially volvulus.Gas noted along the anterior aspect of the dilated bowel loop may have represented intraluminal gas or evolving ischemia.A surrounding fluid collection with enhancement of the bowel wall and peritoneum was observed, which could have been reactive or suggestive of infection, and surgical evaluation was recommended.Additional findings included mild bladder wall thickening and perivesical stranding, possibly reactive to adjacent bowel inflammation or consistent with cystitis, as well as a small pericardial effusion and cholelithiasis.Further ct findings included a small pericardial effusion in the lower thorax without evidence of acute airspace disease.The liver exhibited noncirrhotic morphology with stable central hepatic cysts and additional subcentimeter low-attenuation lesions, likely representing cysts or hemangiomas.Cholelithiasis was present without evidence of cholecystitis or biliary ductal dilation.The pancreas appeared normal, with no focal masses or ductal dilation.The spleen was normal in size, and no adrenal nodules were identified.The kidneys and ureters showed no hydronephrosis, calculi, or solid masses.The urinary bladder demonstrated mild wall thickening and perivesical stranding.The rectum and distal small bowel were decompressed, with rectal wall thickening noted, likely reactive.No lymphadenopathy was observed.The abdominal aorta and major venous structures, including the hepatic, portal, splenic, and superior mesenteric veins, were patent and normal in caliber.No acute or aggressive osseous abnormalities were identified, although mild multilevel degenerative disc disease was present.Later on (b)(6) 2025, an abdominal x-ray demonstrated that the enteric tube was in place, with the sidehole positioned at the gastroesophageal (ge) junction and the tip in the proximal stomach.Advancement of approximately 5 cm was recommended to optimize positioning.Multiple dilated small bowel loops were again observed, partially opacified with contrast, consistent with obstruction previously identified on ct.On (b)(6) 2025, surgical pathology evaluation identified a segment of small bowel with transmural ischemic necrosis.On (b)(6) 2026, the patient presented for clinical evaluation related to attention and concentration deficits.Note: this manufacturer report pertains to the first of two devices implanted in the same procedure.
|
| |
|
Additional Manufacturer Narrative
|
|
Block h2: correction to blocks b2: outcomes attrib to adv event and h6: patient code.Block b3 date of event:
the exact event onset date is unknown.The provided event date of (b)(6)2023, was chosen as a best estimate based on the date of mesh implant.Block e1:
this event was reported by the patient's legal representation.The implanting physician is:
dr.(b)(6).(b)(6) hospital.(b)(6)
united states.Phone: (b)(6).Block h6:
the following imdrf patient codes capture the reportable events of:
e2328 - bowel obstruction.E2327 - necrosis.E2326 - inflammation.E1906 - infection.E2330 - pain.E1002 - abdominal pain.
|
| |
|
Additional Manufacturer Narrative
|
|
Block h2: device evaluation.Block h11:
with all the available information, boston scientific concludes that the reported adverse events of bowel obstruction, necrosis, inflammation, injury, nos (not otherwise specified), infection, unspecified kidney or urinary problem, pain, vomiting, nausea, prolapse, unspecified mental, emotional, or behavioural problem, and high white blood cell count are known risks of the surgical procedure.The device was not returned for evaluation; therefore, a technical analysis could not be performed, and the reported incident could not be confirmed.The device history record (dhr) confirmed that the device met specification prior to shipping.No manufacturing deviations were noted that could have contributed to the event reported.A review of the device instructions for use (ifu) was completed and did not reveal any evidence of device misuse, off label use, or failure to follow instructions.The investigation concluded that the most probable cause for this event is known inherent risk of device, which indicates that the reported adverse event is known and documented in the labeling (including both short or long term known complications or adverse reactions).Block b3 date of event:
the exact event onset date is unknown.The provided event date of (b)(6) 2023, was chosen as a best estimate based on the date of mesh implant.Block e1:
this event was reported by the patient's legal representation.The implanting physician is:
dr.(b)(6).(b)(6) hospital.(b)(6).United states (b)(6).Phone: (b)(6).Block h6:
the following imdrf patient codes capture the reportable events of:
e2328 - bowel obstruction.E2327 - necrosis.E2326 - inflammation.E1906 - infection.E2330 - pain.E1002 - abdominal pain.
|
| |
|