• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. IMPLANT SYSTEM, SUTURELOC; NON-DEGRADABLE FIXATN FASTENER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. IMPLANT SYSTEM, SUTURELOC; NON-DEGRADABLE FIXATN FASTENER Back to Search Results
Model Number IMPLANT SYSTEM, SUTURELOC
Medical Device Problem Code Device Dislodged or Dislocated (2923)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/21/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Event or Problem Description
On 27-jan-2026, a sales representative reported via phone that an ar-4551 sutureloc, and an ar-1588rtt2-ib fibertag® tightrope failed during use.This occurred during an acl reconstruction on (b)(6) 2026 when the ar-4551 sutureloc anchor pulled through the tibia.The ar-1588rtt2-ib fibertag® tightropes suture broke at the button.All portions of the ar-4551 were removed from the patient, while the suture from the ar-1588rtt2-ib was attached to the graft and remains in the patient, but the button was removed.The procedure continued using devices from another manufacturer.This event resulted in approximately a 30-minute delay, and it is unknown if additional anesthesia was administered.The patient had poor bone quality, and the bone was prepped with the kit's drill.There were no adverse effects on the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IMPLANT SYSTEM, SUTURELOC
Common Device Name
NON-DEGRADABLE FIXATN FASTENER
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key24332097
Report Number1220246-2026-00571
Device Sequence Number11990526
Product Code MBI
UDI-Device Identifier00888867425316
UDI-Public(01)00888867425316(11)250805(17)300531(10)15477567
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
PMA/510(K) Number
K223284
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 05/29/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberIMPLANT SYSTEM, SUTURELOC
Device Catalogue NumberAR-4551
Device Lot Number15477567
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/27/2026
Supplement Date Received by Manufacturer05/29/2026
Initial Report FDA Received Date02/13/2026
Supplement Report FDA Received Date05/29/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/05/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-