Catalog Number CHG010
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Unspecified Musculoskeletal problem (4535)
Date of Event 01/23/2026
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Device is not available for evaluation.If additional information is received, it will be reported on a supplemental report.
 
Event or Problem Description
It was reported that the tmj devices require revision for an unknown reason.
 
Event or Problem Description
No new information.
 
Additional Manufacturer Narrative
Additional information: d4, d6a, h4, h6.Correction: d2a.The reported removal of tmj devices due to insufficient joint function could not be confirmed.Review of the available clinical information and imaging indicated possible fibrous connective tissue development or early heterotopic ossification; however, insufficient information was available to determine the cause of the reported symptoms or the planned bilateral revision.No product related failure mode was identified during the investigation.Based on the investigation, there is no indication for an incorrectly working product or any design, material, or manufacturing related issue.Therefore, no corrective and/or preventive actions are deemed necessary at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TMJ UNILATERAL IMPLANT
Common Device Name
Joint, Temporomandibular, Implant
Manufacturer (Section D)
TMJ SOLUTIONS, LLC DBA TMJ CONCEPTS
6059 king drive
ventura 93003
Manufacturer (Section G)
TMJ Solutions, LLC dba TMJ Concepts
6059 king drive
ventura 93003
Manufacturer Contact
elena gehring
boetzingerstr. 41
freiburg D-791-11
GM   D-79111
+49()7614888208
MDR Report Key24377324
Report Number0002031049-2026-00008
Device Sequence Number20246506
Product Code LZD
UDI-Device Identifier07613327626551
UDI-Public07613327626551
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Reporter Type Manufacturer
Report Source Company Representative
Type of Report Initial,Followup
Report Date (Section B) 09/14/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Expiration Date01/01/2023
Device Catalogue NumberCHG010
Device Lot NumberT20-0562
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/23/2026
Supplement Date Received by Manufacturer01/23/2026
Initial Report FDA Received Date02/18/2026
Supplement Report FDA Received Date09/14/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured04/01/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-