W. L. GORE & ASSOCIATES, INC. GORE® MOLDING & OCCLUSION BALLOON CATHETER; CATHETER, INTRAVASCULAR OCCLUDING, TEMPORARY
|
Back to Search Results |
|
| Catalog Number |
MOB37 |
| Medical Device Problem Code |
Improper or Incorrect Procedure or Method (2017)
|
| Health Effect - Clinical Code |
Perforation of Vessels (2135)
|
| Date of Event |
01/27/2026
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
A.2.Patient dob/age was asked but not available.H.6.Investigation findings code c21: conclusions pending results of product history review.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Event or Problem Description
|
|
The following was reported to gore: on (b)(6) 2026, a patient was being treated for an abdominal aortic aneurysm using a gore® excluder® aaa endoprosthesis system.A gore® molding & occlusion balloon was used for ballooning.After deployment of a plc141000 device, the physician ballooned the iliac artery.While the physician was ballooning, something in the iliac appeared to pop on the fluoro, and about 5 seconds later the patient's blood pressure dropped.The physician took an angio and saw that the iliac had ruptured with extravasation.The physician relined the iliac artery with two plc121400 devices.The rupture was resolved, and the patient tolerated the procedure, and was discharged from the hospital (b)(6) 2026.Reportedly, the iliac artery was stenotic and calcified prior to the procedure.
|
| |
|
Additional Manufacturer Narrative
|
|
H.6.Type of investigation code b18: the device was discarded at the treating facility and was therefore not available for analysis.H.6.Investigation findings code c19: the device history record was reviewed to ensure that each manufacturing and inspection operation was performed and indicated the product met creagh medical specifications and procedures.H.6.Investigation conclusions code d15: there is insufficient information available for gore to reasonably draw conclusions related to aspects of the event, therefore conclusion code ¿d15: cause not established¿ is being used.Insufficient information may include limited or missing relevant medical records, involvement of multiple implanted devices (including non-gore devices) in the field of treatment, patient non-compliance, and/or a general lack of available detail or specificity related to an adverse event and/or device.
|
| |
|