| Model Number |
3401 |
| Medical Device Problem Codes |
Inappropriate/Inadequate Shock/Stimulation (1574); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Codes |
Shock from Patient Lead(s) (3162); No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/03/2026
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that this subcutaneous implantable cardioverter defibrillator system was abandoned due to a product performance issue.A transvenous system was successfully implanted.No additional adverse patient effects were reported.The abandoned system remains implanted.
|
| |
|
Event or Problem Description
|
|
This supplemental report is being filed to provide additional information that the system was abandoned due to inappropriate shocks.There were no additional adverse patient effects.The system remains implanted.It was reported that this subcutaneous implantable cardioverter defibrillator system was abandoned due to a product performance issue.A transvenous system was successfully implanted.No additional adverse patient effects were reported.The abandoned system remains implanted.
|
| |
|
Event or Problem Description
|
|
This supplemental report is being filed to provide additional information for the h11 section of tab h.Device manufacturers only.This supplemental report is being filed to provide additional information that the system was abandoned due to inappropriate shocks.There were no additional adverse patient effects.The system remains implanted.It was reported that this subcutaneous implantable cardioverter defibrillator system was abandoned due to a product performance issue.A transvenous system was successfully implanted.No additional adverse patient effects were reported.The abandoned system remains implanted.
|
| |
|
Additional Manufacturer Narrative
|
|
The device was not returned for analysis as it remains implanted; therefore, a technical analysis could not be performed.A review of the device history record (dhr) was performed.The review of the dhr identified that there were no process related non-conformances, scrap, or rework performed during the production that could explain the event.The reviews ensure each device meets specification prior to release for use.There is no indication the device manufacturing process contributed to the reported complaint.A risk review was completed and confirmed that the event of inappropriate shock was defined in the risk documentation.This event type has been accounted for during product risk analysis to support acceptable risk benefit for the product.Review of labeling determined that the complaint situation was listed in the manual.There was no indication in the complaint that the product was not used in accordance to labeling.The manual was unlikely to be the cause of the reported complaint; translation, wording, or graphics does not require further review.Based on a thorough review of the reported complaint, boston scientific has assigned an investigation conclusion code of known inherent risk of device.
|
| |
|