• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ETHICON ENDO-SURGERY, LLC. PROXIMATE; STAPLE, IMPLANTABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON ENDO-SURGERY, LLC. PROXIMATE; STAPLE, IMPLANTABLE Back to Search Results
Catalog Number TLC75
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Failure to Anastomose (1028); Abscess (1690); Post Operative Wound Infection (2446)
Date of Event 02/11/2025
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Date sent: 2/24/2026 d4: batch # unk d4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.D4: udi: the expiration date is currently not available.Therefore, the full udi is currently not available.An analysis of the product could not be performed since a physical sample was not received for evaluation.An evaluation of the manufacturing record could not be performed as the required product identification number was not provided to complete the evaluation.As part of our company quality system process, all devices are manufactured, inspected, and distributed to approved specifications.Additional information:: do the surgeons fire the device or someone else? the surgeon but unsure about the other surgeon do they use any purse string or other techniques? unsure they used to use manual and transition to manual? they used to use medtronic and switched to jnj do they wait 15 seconds during dialing down? they have been in-service and have the ifu.Unsure of actual practice.Have they seen any malformed staples? unsure how do they conduct their leak test? the anastomosis have all passed the leak tests when was the last time they saw the surgeon actually fire the device in a case? they do not want case support.Are they crossing staple lines? unsure what technique do they use to remove the device? unsure what is the doctors goal? 1 surgeon this report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Event or Problem Description
It was reported that the patient underwent a colectomy with colostomy and anastomosis procedure.A small anastomotic leak with associated abscess was subsequently identified.The device used during the procedure was discarded and is not available for return or evaluation.No other information provided.
 
Additional Manufacturer Narrative
(b)(4) date sent: 4/6/2026.Additional information was requested and the following was obtained: an external rapid response call was held to include post market surveillance, customer quality, quality engineering, quality, design engineering, marketing, the local team, and the operating surgeon to discuss the complaint.The surgeon has experienced an increase in surgical site infections due to anastomotic leaks.When using the device, he has experienced issues with the ease of use of the device, compression of the tissue, and ease of extraction.The surgeon indicated he always is pulling during an extraction; it has never been smooth.There is always tension.His current process for division and anastomosis is usually the triple staple technique and, at times, the side-to-side anastomoses.The resident, pa or the surgeon, himself, always does the device firing.They have tried many different techniques.Procedures are being minimally invasive.It is putting undue stress on the anastomosis, which is already delicate.Having to stretch the anastomosis is the main issue for the surgeon.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PROXIMATE
Common Device Name
STAPLE, IMPLANTABLE
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
Manufacturer (Section G)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
Manufacturer Contact
orla o'mahony
475 calle c
guaynabo 
3035526892
MDR Report Key24433279
Report Number3005075853-2026-01587
Device Sequence Number16013531
Product Code GDW
UDI-Device Identifier10705036013211
UDI-Public10705036013211
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K020779
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 04/06/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberTLC75
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/28/2026
Supplement Date Received by Manufacturer03/18/2026
Initial Report FDA Received Date02/24/2026
Supplement Report FDA Received Date04/06/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-