| Medical Device Problem Code |
Activation Problem (4042)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/26/2026
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that when removing the safestep after use, health professional felt a snagging sensation on the needle, preventing proper needle retraction.No needle stick injury and no serious harm occurred.No other information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The manufacturer has received the sample and will be evaluated.A supplemental will be submitted with evaluation results.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The complaint of difficulty advancing the safety mechanism was confirmed and the cause was determined to be supplier related.The product returned for evaluation was one 20g safestep infusion set without y-site.The investigation findings were consistent with misplaced or excess manufacturing adhesive, which bound the safety mechanism to the needle.The following observations were made during the sample evaluation: ¿ the safety mechanism was not engaged over the needle tip and was returned positioned at the needle base.¿ the needle shaft and safety mechanism were both examined and were determined to be undamaged and thus were not suspected to have contributed towards the event.Microscopic examination under uv light assistance revealed a white/clear adhesive-like substance at the interface of the needle shaft and safety mechanism.That material fluoresced under ultraviolet light, which was consistent with the adhesive used to assemble the infusion set.From this, it appeared that adhesive was deposited on the needle shaft during device manufacture.The device is a supplied component and the supplier was notified of the event.This complaint will be recorded for future trending and monitoring purposes.
|
| |
|
Search Alerts/Recalls
|