| Catalog Number |
47530300M |
| Medical Device Problem Code |
Burst Container or Vessel (1074)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/19/2026
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Additional information is pending and will be submitted within 30 days upon receipt.
|
| |
|
Event or Problem Description
|
|
As reported, the 3.0 x 300 saberx percutaneous transluminal coronary angioplasty (ptca) balloon passed through the non-cordis fixed catheter (fc).However, the balloon ruptured before reaching nominal pressure/size.Afterwards, a 3.0 x 200 saberx balloon was used and the procedure was completed without patient injury.Additional information was requested but not provided.The device will be returned for evaluation.
|
| |
|
Event or Problem Description
|
|
As reported, the 3.0 x 300 saberx percutaneous transluminal angioplasty (pta) balloon passed through the non-cordis fixed catheter (fc).However, the balloon ruptured before reaching nominal pressure/size.Afterwards, a 3.0 x 200 saberx balloon was used and the procedure was completed without patient injury.Additional information was requested but not provided.The device will be returned for evaluation.
|
| |
|
Additional Manufacturer Narrative
|
|
As reported, the 3.0 x 300 saberx percutaneous transluminal angioplasty (pta) balloon passed through the non-cordis fixed catheter (fc).However, the balloon ruptured before reaching nominal pressure/size.Afterwards, a 3.0 x 200 saberx balloon was used and the procedure was completed without patient injury.Additional information was requested but not provided.The device was not returned for evaluation.A product history record (phr) review of lot 2506199619 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.The reported ¿balloon burst - at/below rbp¿ could not be verified as the device was not returned for analysis.The exact cause could not be determined.Vessel characteristics, procedural factors or device handling may have contributed to the reported event.However, without the return of the device for analysis, and with the limited amount of information provided, it is difficult to draw a clinical conclusion between the device and the event reported.According to the instructions for use, which are not intended to mitigate risk, ¿carefully inspect the catheter prior to use to verify that the catheter has not been damaged and that its size, shape and condition are suitable for the procedure for which it is to be used.Flush or rinse all products entering the vascular system with sterile isotonic saline or a similar solution via the guide-wire access port prior to use.Never attempt to move the guide wire when the balloon is inflated.Do not advance the catheter against significant resistance.The cause of resistance should be determined via fluoroscopy.Inflation in excess of the rated burst pressure may cause the balloon to rupture.Use the recommended balloon inflation medium (25% contrast medium/75% sterile saline solution).It has been shown that a 25/75% contrast / saline ratio has yielded faster balloon inflation / deflation times.Never use air or other gaseous medium to inflate the balloon.If resistance is felt during post procedure withdrawal of the catheter through the introducer sheath, determine if contrast is trapped in the balloon with fluoroscopy.If contrast is present, push the balloon out of the sheath and then completely evacuate the contrast before proceeding to withdraw the balloon.If resistance is still felt during post procedure withdrawal of the catheter, it is recommended to remove the balloon catheter and guidewire/ introducer sheath as a single unit.Do not continue to use the balloon catheter if the shaft has been bent or kinked.¿ neither the phr nor the information available suggests a design or manufacturing related cause for the reported event.Therefore, no corrective or preventive action will be taken at this time.
|
| |
|