AESCULAP AG AS VEGA System® PS; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Model Number |
NX011Z |
| Medical Device Problem Code |
Patient-Device Incompatibility (2682)
|
| Health Effect - Clinical Code |
Failure of Implant (1924)
|
|
Type of Reportable Event
|
Serious Injury
|
|
|
|
|
| |
|
Event or Problem Description
|
|
An outside law firm reported that a patient experienced issues following a left knee prosthesis that required subsequent medical intervention.According to the operative report dated (b)(6) 2021, the patient underwent a primary left total knee arthroplasty for tricompartmental degenerative joint disease (djd) with marked tibial torsion.The procedure was performed using aesculap components, which were cemented in place using palacos bone cement.The operative report indicates that the components were implanted with appropriate alignment and stability, and the patient was taken to recovery in good condition.No intraoperative complications were reported.According to a subsequent operative report dated (b)(6) 2023, the patient underwent left knee manipulation under anesthesia due to postoperative adhesive capsulitis.The procedure involved manipulation of the knee from full extension to approximately 125 degrees of flexion.No audible or palpable abnormalities were noted, and no structural changes to the knee were identified during the procedure.The patient tolerated the procedure well and was taken to recovery in good condition.No intraoperative complications were reported.
|
| |
|
Event or Problem Description
|
|
An outside law firm reported that a patient experienced issues following a left knee prosthesis that required subsequent medical intervention.According to the operative report dated on (b)(6) 2021, the patient underwent a primary left total knee arthroplasty for tricompartmental degenerative joint disease (djd) with marked tibial torsion.The procedure was performed using aesculap components, which were cemented in place using palacos bone cement.The operative report indicates that the components were implanted with appropriate alignment and stability, and the patient was taken to recovery in good condition.No intraoperative complications were reported.According to a subsequent operative report dated on (b)(6) 2023, the patient underwent left knee manipulation under anesthesia due to postoperative adhesive capsulitis.The procedure involved manipulation of the knee from full extension to approximately 125 degrees of flexion.No audible or palpable abnormalities were noted, and no structural changes to the knee were identified during the procedure.The patient tolerated the procedure well and was taken to recovery in good condition.No intraoperative complications were reported.Subsequently, the left total knee arthroplasty failed due to loosening of the implanted components.On (b)(6) 2025, the patient underwent revision left total knee arthroplasty for a failed loose left total knee.During surgery, the surgeon documented that the femoral component was loose and could be removed easily.The cement remained attached to the bone while the femoral component demonstrated very limited cement attachment.The tibial component was also easily removed.Significant synovitis and joint fluid were present.No significant bone loss was noted.Revision of both components was performed using implants from another manufacturer.The patella was retained.No intraoperative complications were reported.The patient was taken to recovery in good condition.This report is filed under ais reference (b)(4).
|
| |
|
Search Alerts/Recalls
|
|
|