• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: PROCEPT BIOROBOTICS CORPORATION AQUABEAM ROBOTIC SYSTEM; FLUID JET REMOVAL SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

PROCEPT BIOROBOTICS CORPORATION AQUABEAM ROBOTIC SYSTEM; FLUID JET REMOVAL SYSTEM Back to Search Results
Catalog Number AB2000
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Hemorrhage/Blood Loss/Bleeding (1888)
Date of Event 03/09/2026
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The aquabeam robotic system is a reusable device; therefore, it is currently in the possession of the user facility.The investigation of this event consisted of a review of the treatment log files, device history record (dhr) and instruction for use (ifu).A review of the device history record (dhr) was conducted for ab2000-b/serial number (b)(6), which confirmed that there were no non-conformances, failures, discrepancies, or missed steps during the manufacturing process that could be related to the reported event.The review indicated that the system met all design and manufacturing specifications when released for distribution.The aquabeam robotic system's treatment log files were reviewed, which confirmed no malfunction occurred.The review of the treatment log files revealed that the aquabeam robotic system functioned as intended, as no malfunction was observed during aquablation therapy.The aquabeam robotic system's instruction for use (ifu), ifu0101-00, rev.E, was reviewed.4.3 warnings: procedure as with any surgical urologic procedure, potential perioperative risks of the aquablation procedure include: bleeding.8.32 sterile: a.After the aquabeam handpiece removal, follow the standard clot evacuation procedure to remove clots and tissue with a cystoscopic sheath by using an ellik bladder evacuator or toomey syringe.B.Use one of the following methods to achieve hemostasis: cautery followed by foley balloon catheter insertion.Under spinal anesthesia, insert a balloon catheter in the bladder with bladder neck traction then fill the bladder with sterile saline and maintain for approximately 30-60 minutes before starting cbi (continuous bladder irrigation) balloon catheter in bladder with bladder neck traction balloon catheter in prostatic fossa: inflate balloon with 5cc in the bladder.Under trus guidance retract balloon into prostatic fossa, inflate balloon to 30-50% of initial prostate volume, apply mild traction on the catheter to hold the balloon catheter in place, balloon catheter in bladder, no traction, c.Start cbi per hospital protocol.The aquabeam robotic system is a reusable device; therefore, it is still currently in possession of the user facility.The aquabeam robotic system's ifu lists bleeding as a potential risk of aquablation therapy and provides adequate instructions to achieve hemostasis.Based on review of the event details, log files, dhr and ifu, the event is considered not device related.Submission of this report does not constitute an admission that the manufacturer's product caused or contributed to the event.
 
Event or Problem Description
A male patient underwent aquablation therapy to treat symptomatic benign prostatic hyperplasia (bph).Procept biorobotics corporation (procept) became aware that during post-focal bladder neck cautery and prior to discharge, the patient struggled to achieve hemostasis.The surgeon initially managed the patient's bleeding with traction and continuous bladder irrigation (cbi).While the patient was in the post-anesthesia care unit (pacu), the surgeon ordered 1g of tranexamic acid (txa) to help control the bleeding.The patient's hemoglobin level dropped to 5.2 g/dl, necessitating a blood transfusion.After the transfusion, the patient's hemoglobin levels returned to normal.Patient is well and has been discharged.No malfunction of the aquabeam robotic system was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AQUABEAM ROBOTIC SYSTEM
Common Device Name
FLUID JET REMOVAL SYSTEM
Manufacturer (Section D)
PROCEPT BIOROBOTICS CORPORATION
150 baytech dr
san jose CA 95134
Manufacturer (Section G)
PROCEPT BIOROBOTICS CORPORATION
150 baytech dr
san jose CA 95134
Manufacturer Contact
doria esquivel
150 baytech dr
san jose, CA 95134
6502327291
MDR Report Key24662442
Report Number3012977056-2026-00050
Device Sequence Number9289983
Product Code PZP
UDI-Device IdentifierB614AB20001
UDI-Public+B614AB20001/16D20200831D
Combination Product (Y/N)N
Initial Reporter StateAR
Initial Reporter CountryUS
PMA/510(K) Number
DEN170024
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 03/23/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberAB2000
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 03/09/2026
Initial Report FDA Received Date03/23/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured08/31/2021
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device A
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention;
Patient SexMale
-
-