MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION MANTIS; HEMOSTATIC METAL CLIP FOR THE GI TRACT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION MANTIS; HEMOSTATIC METAL CLIP FOR THE GI TRACT Back to Search Results
Model Number M00521421
Medical Device Problem Codes Break (1069); Activation, Positioning or Separation Problem (2906)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/25/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported to boston scientific corporation that a mantis clip was used during an endoscopy procedure on (b)(6) 2026.During the procedure, the mantis clip locked onto tissue, but the handle and spring wire broke, and manipulation of moving left and right, trying to reposition catheter, trying to bend to angle and pull trying to torque to get the clip to release.The clip ultimately was released after a reported 20 minutes of manipulation.The procedure was completed with the same device.There were no patient complications reported as a result of this event.Note: this report pertains to the second of two clips used in different procedures.
 
Additional Manufacturer Narrative
Block h6: imrdf code a15 captures the reportable event of difficult to release from catheter.Block h11: investigation results- the device was not returned for analysis as it was discarded; therefore, a technical analysis could not be performed.The complaint device was not returned as it was discarded therefore, product analysis could not be carried out, for this reason and due to the lack of evidence is unable to confirm the reported event.It was confirmed this device met manufacturing specification prior to distribution and there were no manufacturing deviations which could have contributed to the reported event.Based on a thorough review of the reported complaint, boston scientific has assigned an investigation conclusion code of "cause not established".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MANTIS
Common Device Name
HEMOSTATIC METAL CLIP FOR THE GI TRACT
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
2546 calle primera
alajuela
CS  
Manufacturer Contact
christina lam
300 boston scientific way
marlborough, MA 01752
9145716918
MDR Report Key24682047
Report Number3005099803-2026-01077
Device Sequence Number9976978
Product Code PKL
UDI-Device Identifier00191506023607
UDI-Public(01)00191506023607(17)281105(10)37887959
Combination Product (Y/N)N
Initial Reporter StateOR
Initial Reporter CountryUS
PMA/510(K) Number
K221124
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 03/24/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberM00521421
Device Catalogue Number2142
Device Lot Number0037887959
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/25/2026
Initial Report FDA Received Date03/24/2026
Date Device Manufactured11/06/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-