• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON, DICKINSON & CO. (SPARKS) BD BACTEC¿ MGIT¿ MYCOBACTERIA GROWTH INDICATOR TUBES; SYSTEM, BLOOD CULTURING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON, DICKINSON & CO. (SPARKS) BD BACTEC¿ MGIT¿ MYCOBACTERIA GROWTH INDICATOR TUBES; SYSTEM, BLOOD CULTURING Back to Search Results
Catalog Number 245122
Medical Device Problem Code Incorrect, Inadequate or Imprecise Result or Readings (1535)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/27/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
B3.Date of event is unknown.The customer reports events occurred in 2025 and in 2026; however, no further information can be provided.The date received by manufacturer has been used for this field.D4.Medical device expiration date: unknown.H4.Device manufacture date: unknown.A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported while using the bd bactec¿ mgit¿ mycobacteria growth indicator tubes, one (1) false resistant m.Tuberculosis patient result was obtained from a mgit instrument.The customer is unable to provide the number of affected patient samples or tubes used with a specific product lot.No confirmatory testing was reported; however, the customer noted that no actual growth was observed.Repeat testing occurred and no adverse health impact was reported.This is report 55 of 61.
 
Event or Problem Description
It was reported while using the bd bactec¿ mgit¿ mycobacteria growth indicator tubes, one (1) false resistant m.Tuberculosis patient result was obtained from a mgit instrument.The customer is unable to provide the number of affected patient samples or tubes used with a specific product lot.No confirmatory testing was reported; however, the customer noted that no actual growth was observed.Repeat testing occurred and no adverse health impact was reported.This is report 55 of 61.
 
Additional Manufacturer Narrative
Investigation summary: material #: 245122 batch #: unknown defect: no/false reaction background material 245122 is manufactured by rehydrating the media components with usp purified water and thoroughly mixing until a homogeneous solution is obtained.The tubes are filled, capped, torqued and then labeled by machine per standard operating procedure (sop).The tubes are terminally autoclaved in an air over pressure (aop) autoclave, per manufacturing instructions, using a validated cycle.Post autoclaving, tubes are packaged into final shipping configurations.Batch history review no batch number was provided for this complaint investigation.Therefore, trending was done on the appropriate databases for bactec mgit 7ml (material 245122) and no quality notification trends have been identified for this material in the last 12 months.Complaint history the complaint history was reviewed for material 245122 and there are no trends for performance issues in the last 12 months.Return material analysis no physical return samples or photos were provided for this investigation.Investigation as no batch information was provided, retention analysis cannot be performed.All batches are tested prior to release and results reported on the certificate of analysis which can be obtained at www.Bd.Com/regdocs.Tube bactec mgit 7 ml is stability tested biennially for biological performance to ensure satisfactory performance throughout shelf life with the organisms that are reported on the certificate of analysis.Conclusion as no batch number was provided, this complaint cannot be confirmed.No complaint trends for this defect have been identified; no actions are indicated at this time.Bd will continue to trend complaints for defects.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD BACTEC¿ MGIT¿ MYCOBACTERIA GROWTH INDICATOR TUBES
Common Device Name
SYSTEM, BLOOD CULTURING
Manufacturer (Section D)
BECTON, DICKINSON & CO. (SPARKS)
7 loveton circle
sparks MD 21152
Manufacturer (Section G)
BECTON, DICKINSON & CO. (SPARKS)
7 loveton circle
sparks MD 21152
Manufacturer Contact
matt j. connor
7 loveton circle
sparks, MD 21152
4103164000
MDR Report Key24700641
Report Number1119779-2026-00572
Device Sequence Number10463288
Product Code MDB
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K974883
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 06/30/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Catalogue Number245122
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/27/2026
Supplement Date Received by Manufacturer06/23/2026
Initial Report FDA Received Date03/26/2026
Supplement Report FDA Received Date06/30/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-