Catalog Number 1009-00
Medical Device Problem Code Retraction Problem (1536)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/15/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device was not returned for investigation.Therefore, we could not conclusively determine the root cause of the reported incident.Previous investigations into this issue have found the failure was determined to be centering hoop to wire welding error along with operator adjustment error.During the welding process, this centering hoop was likely not properly aligned against its retainer slot.Capa: 2022-025 was previously implemented to address this issue, and no further action is required at this time.The device involved was manufactured after the capa was implemented.Although the issue occurred post-implementation, the overall occurrence of this issue has decreased since the capa was put in place.The production and traceability record for the device was reviewed; no issues were found during manufacturing or packaging that would cause or contribute to the reported event.All quality control tests were completed successfully and met specification.We have not received any other complaints of a similar nature for devices from this lot.
 
Event or Problem Description
It was reported that the lemaitre valvulotome had been used twice, and upon removal from the body, it was observed that the blade would not retract into the sheath.No additional complications or patient injury were reported.It is unknown if the device was checked prior to use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LEMAITRE VALVULOTOME
Common Device Name
VALVULOTOME
Manufacturer (Section D)
LEMAITRE VASCULAR, INC.
63 second ave
burlington MA 01803
Manufacturer (Section G)
LEMAITRE VASCULAR, INC
63 second ave
burlington MA 01803
Manufacturer Contact
peter song
63 second ave
burlington, MA 01803
7814251683
MDR Report Key24711949
Report Number1220948-2026-00056
Device Sequence Number14949646
Product Code MGZ
UDI-Device Identifier00840663106653
UDI-Public(01)00840663106653(11)250129(17)291228(10)ELVH00002748(91)1009-00
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
K140042
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 03/27/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number1009-00
Device Lot NumberELVH00002748
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/25/2026
Initial Report FDA Received Date03/30/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured01/29/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1