• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: IMPLANT DIRECT SYBRON MANUFACT SIMPLY ICONIC SBM IMP 4.7X3.4 PLAT 08MML; ENDOSSEOUS DENTAL IMPLANT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

IMPLANT DIRECT SYBRON MANUFACT SIMPLY ICONIC SBM IMP 4.7X3.4 PLAT 08MML; ENDOSSEOUS DENTAL IMPLANT Back to Search Results
Catalog Number 674708RP
Medical Device Problem Code Premature Separation (4045)
Health Effect - Clinical Codes Inadequate Osseointegration (2646); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/26/2026
Type of Reportable Event Serious Injury
Event or Problem Description
Component not retained on mating part.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SIMPLY ICONIC SBM IMP 4.7X3.4 PLAT 08MML
Common Device Name
ENDOSSEOUS DENTAL IMPLANT
Manufacturer (Section D)
IMPLANT DIRECT SYBRON MANUFACT
3050 east hillcrest drive
thousand oaks CA 91362
Manufacturer (Section G)
IMPLANT DIRECT SYBRON MANUFACT
3050 east hillcrest drive
thousand oaks CA 91362
Manufacturer Contact
anitha mechery
3050 east hillcrest drive
thousand oaks 91362
8057785975
MDR Report Key24728782
Report Number3001617766-2026-006115
Device Sequence Number18463213
Product Code DZE
UDI-Device Identifier10841307125174
UDI-Public(01)10841307125174(10)15030486(17)301208
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K201553
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Other Health Care Professional
Remedial Action Replace
Type of Report Initial
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number674708RP
Device Lot Number15030486
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date03/30/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured12/09/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age55 YR
Patient SexUnknown
-
-