| Model Number |
GWC-12325LG-FT |
| Medical Device Problem Codes |
Material Separation (1562); Device Damaged by Another Device (2915)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/19/2026
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The device was not returned for analysis.Production record and corrective and preventative actions (capa) reviews were performed and revealed no indication of a product quality issue.Additionally, a query of the complaint handling database for the reported lot revealed there is no indication of a lot specific issue.Based on the information received, the investigation determined that the reported device damaged by another device, material separation and unexpected medical intervention appears to be related to user error.In this case, per reported details, the material separation is due to not maintaining adequate distance between the driveshaft and spring tip.It was reported that the oad driveshaft came in contact with the viperwire guide wire spring tip, leading to the spring tip fracturing.The diamondback 360® coronary orbital atherectomy system instruction for use (ifu), warns: ¿use fluoroscopy to monitor and maintain spacing between the driveshaft and guide wire spring tip throughout the procedure.Always keep more than 5mm of spacing between the distal end of the oad driveshaft and the proximal end of the guide wire spring tip.If the distance between the driveshaft tip and the viperwire guide wire spring tip is insufficient, the driveshaft tip may contact the guide wire spring tip and result in dislodging the guide wire spring tip.¿ based on the results of the complaint investigation, there is no indication of a product quality issue with respect to the design, manufacture, or labeling of the device.Updated: h6 (codes 4118, 3233, and 11 no longer apply).
|
| |
|
Event or Problem Description
|
|
It was reported the diamondback 360 coronary orbital atherectomy device (oad) was being used to treat a heavily calcified right coronary artery (rca).After six antegrade treatments, the oad was advanced too close to the viperwire guide wire spring tip, which led to the viperwire fracturing.The fractured component was able to be snared.There were no patient complications were reported as a result of the event.The patient was in stable condition.
|
| |
|
Event or Problem Description
|
|
It was reported the diamondback 360 coronary orbital atherectomy device (oad) was being used to treat a heavily calcified right coronary artery (rca).During the procedure, the oad was advanced too close to the viperwire guide wire spring tip, which led to the viperwire fracturing.The fractured component was able to be snared.There were no patient complications were reported as a result of the event.The patient was in stable condition.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer's investigation is still pending at this time.Results and conclusions will be provided in the final report.
|
| |
|