| Model Number |
429878 |
| Medical Device Problem Codes |
Failure to Capture (1081); Impedance Problem (2950); High Capture Threshold (3266)
|
| Health Effect - Clinical Code |
Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
03/10/2026
|
|
Type of Reportable Event
|
Death
|
|
Event or Problem Description
|
|
It was reported that the right atrial (ra) lead displayed undersensing resulting in unnecessary pacing at times and false termination of atrial tachycardia/atrial fibrillation (at/af) events.Approximately three days later, the patient passed away.A remote monitoring transmission was sent the next day and indicated there were high ra lead and left ventricular (lv) lead thresholds.Additionally, the ra lead, lv lead, and right ventricular (rv) lead displayed a loss of capture in pacing impedances.
|
| |
|
Additional Manufacturer Narrative
|
|
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
It was reported that the right atrial (ra) lead displayed undersensing resulting in unnecessary pacing at times and false termination of atrial tachycardia/atrial fibrillation (at/af) events.Approximately three days later, the patient passed away.A remote monitoring transmission was sent the next day and indicated there were high right ventricular (rv) lead and left ventricular (lv) lead thresholds.Additionally, the ra lead, lv lead, and rv lead displayed a loss of capture and rising pacing impedances.
|
| |
|
Additional Manufacturer Narrative
|
|
Correction: b5.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|