• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COVIDIEN SURGICAL POLYSORB; SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC AC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COVIDIEN SURGICAL POLYSORB; SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC AC Back to Search Results
Model Number CL-803
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/23/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during a total knee replacement, needle detachment occurred on the 18 sutures while removing the needle from the retainer.A product from a different lot number was used to resolve the issue.No patient complications have been reported as a result of this event.
 
Additional Manufacturer Narrative
D10 concomitant product: cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) cl-803 polysorb* 1 vio 75cm gs24 x36 (lot#: a5a1768y) medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POLYSORB
Common Device Name
SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC AC
Manufacturer (Section D)
COVIDIEN SURGICAL
60 middletown ave
north haven CT 06473
Manufacturer (Section G)
COVIDIEN SURGICAL
60 middletown ave
north haven CT 06473
Manufacturer Contact
mike bocchino
8200 coral sea st ne
mounds view, MN 55112-4391
8006464633
MDR Report Key24865907
Report Number1219930-2026-02429
Device Sequence Number9367774
Product Code GAM
UDI-Device Identifier10884521041868
UDI-Public(01)10884521041868(17)291231(10)A5A1768Y(20)01
Combination Product (Y/N)N
Initial Reporter CountryKS
PMA/510(K) Number
K963253
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 06/25/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberCL-803
Device Catalogue NumberCL-803
Device Lot NumberA5A1768Y
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/08/2026
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/23/2026
Supplement Date Received by Manufacturer06/15/2026
Initial Report FDA Received Date04/13/2026
Supplement Report FDA Received Date06/25/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/15/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SEE NOTE ON H11
Patient SexUnknown
-
-