Model Number
TRXP3812
Medical Device Problem Code
Failure to Osseointegrate (1863)
Health Effect - Clinical Code
Insufficient Information (4580)
Date of Event
03/26/2026
Type of Reportable Event
Serious Injury
Event or Problem Description
Implant failed to osseointegrate.
Search Alerts/Recalls
New Search
|
Submit an Adverse Event Report
Brand Name
BIOHORIZONS INC.
Common Device Name
DENTAL IMPLANT
Manufacturer
(Section D)
BIOHORIZONS INC.
2300 riverchase center
birmingham AL 35244
Manufacturer
(Section G)
BIOHORIZONS INC.
2300 riverchase center
birmingham AL 35244
Manufacturer Contact
anissa smith
2300 riverchase center
birmingham, AL 35244
MDR Report Key
24954352
Report Number
1060818-2026-07788
Device Sequence Number
12078473
Product Code
DZE
UDI-Device Identifier
00847236012717
UDI-Public
00847236012717
Combination Product (Y/N)
N
Initial Reporter Country
SP
PMA/510(K) Number
K223697
Number of Events Summarized
1
Summary Report (Y/N)
N
Serviced by Third Party (Y/N)
N
Reporter Type
Manufacturer
Report Source
Company Representative
Initial Reporter Occupation
Dentist
Type of Report
Initial
Report Date
(Section B)
04/25/2026
1
Device was Involved in the Event
1
Patient was Involved in the Event
Is this an Adverse Event Report?
Yes
Is this a Product Problem Report?
No
Operator of Device
Health Professional
Device Expiration Date
09/05/2024
Device Model Number
TRXP3812
Device Catalogue Number
TRXP3812
Device Lot Number
1905407
Is the Reporter a Health Professional?
Yes
Type of Report(Section G)
Thirty-Day
Initial Date Received by Manufacturer
03/26/2026
Initial Report FDA Received Date
04/22/2026
Date Device Manufactured
09/06/2019
Is the Device Labeled for Single Use? (Y/N)
Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device
Initial
Patient Sequence Number
1
Outcome Attributed to Adverse Event
Required Intervention;
Patient Sex
Unknown
-
-