| Model Number |
CA500 |
| Medical Device Problem Code |
Failure to Fire (2610)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
Procedure performed: laparoscopic cholecystectomy event description: the event date is unknown.The customer reported that about five or six different clip appliers (likely from the same lot) did not deploy the first (or first and second clip) correctly.There was either no clip or a damaged clip.After some "plastic to plastic" usages the following clips worked just fine.The physicians are trained to use the clip applier correctly and they are not preloading the clipapplier before entering the trocar.I talked to the chief physician about those incidents and he assured me that he has been using the clip appliers the same way he always had.No clinical impact to the patient as a result of the event.Additional information received from applied medical representative via email on 13apr26: the customer purchased it as a kit.Event dates are different, basically in the 3 weeks prior to the event date.I can not confirm if all the incident devices belonged to lot 1559037.But the customer told me that they never had issues before or after.They think they all belonged to the same lot.I can not clarify it though.4 of the clip appliers did not apply any clips for the first few "plastic to plastics".1-2 provided damaged clips.Intervention: after multiple "plastic to plastic" usages, the clipapplier worked just fine.Patient status: patient is fine.
|
| |
|
Additional Manufacturer Narrative
|
|
The event unit is not being returned to applied medical for evaluation.A follow-up report will be provided upon completion of the investigation.
|
| |
|
Additional Manufacturer Narrative
|
|
The event unit was not returned to applied medical for evaluation.As the event unit was not returned, applied medical is unable to determine if the event unit exhibited any non-conformances that could have contributed to the reported event.In the absence of the event unit, it is difficult to determine if the reported event was caused by a manufacturing non-conformance or circumstantial factors at the time of use.Applied medical has reviewed the details surrounding the event and is unable to determine the exact root cause of the event.Applied medical has performed a historical trend analysis and review of production records and no relevant documentation was identified.
|
| |
|
Event or Problem Description
|
|
Procedure performed: laparoscopic cholecystectomy event description: event date is unknown.The customer reported that about five or six different clip appliers (likely from the same lot) did not deploy the first (or first and second clip) correctly.There was either no clip or a damaged clip.After some "plastic to plastic" usages the following clips worked just fine.Sadly, they only kept one of those clip appliers, ready for pickup.The physicians are trained to use the clipapplier correctly and they are not preloading the clipapplier before entering the trocar.I talked to the chief physician about those incidents and he assured me that he has been using the clip appliers the same way he always had.No clinical impact to the patient as a result of the event.Additional information received from applied medical representative via email on 13apr26: the customer purchased it as a kit.Event dates are different, basically in the 3 weeks prior to the event date.I can not confirm if all the incident devices belonged to lot 1559037.But the customer told me that they never had issues before or after.They think they all belonged to the same lot.I can not clarify it though.4 of the clip appliers did not apply any clips for the first few "plastic to plastics".1-2 provided damaged clips.Additional information received from applied medical representative via email on 29apr26: unfortunately, there is no information on the lot number of the kit.[applied medical supplied the customer with photos and asked the customer to identify which malfunctions they experienced.] photo b most accurately represents how the clips were damaged.Cff03 was used the clip was properly seated.A clip wasn't loaded into the jaws prior to the instrument¿s insertion/removal through the trocar a loaded clip was not manually removed from the jaws, so the device did not need to be actuated/reset.It wasn't necessary to manually remove the clip.The trigger could be easily and completely actuated intervention: after multiple "plastic to plastic" usages, the clipapplier worked just fine.Patient status: patient is fine.
|
| |
|