MAUDE Adverse Event Report: ALTATEC ALTATEC; DENTAL IMPLANT
FDA Home
Medical Devices
Databases
-
510(k)
|
DeNovo
|
Registration & Listing
|
Adverse Events
|
Recalls
|
PMA
|
HDE
|
Classification
|
Standards
CFR Title 21
|
Radiation-Emitting Products
|
X-Ray Assembler
|
Medsun Reports
|
CLIA
|
TPLC
ALTATEC ALTATEC; DENTAL IMPLANT
Back to Search Results
Model Number
K1054.3816
Medical Device Problem Code
Failure to Osseointegrate (1863)
Health Effect - Clinical Code
Insufficient Information (4580)
Date of Event
03/26/2026
Type of Reportable Event
Serious Injury
Event or Problem Description
Implant failed to osseointegrate.
Search Alerts/Recalls
New Search
|
Submit an Adverse Event Report
Brand Name
ALTATEC
Common Device Name
DENTAL IMPLANT
Manufacturer
(Section D)
ALTATEC
maybachstrasse 5
wimsheim 71299
GM 71299
MDR Report Key
24974199
Report Number
1060818-2026-60059
Device Sequence Number
17372327
Product Code
DZE
UDI-Device Identifier
E219K105438161
UDI-Public
E219K105438161
Combination Product (Y/N)
N
Initial Reporter State
IL
Initial Reporter Country
US
Number of Events Summarized
1
Summary Report (Y/N)
N
Device Implanted Year
2025
Device Explanted Year
2025
Serviced by Third Party (Y/N)
N
Reporter Type
Importer
Report Source
Company Representative
Initial Reporter Occupation
Dentist
Type of Report
Initial
Report Date
(Section B)
04/25/2026
1
Device was Involved in the Event
1
Patient was Involved in the Event
Is this an Adverse Event Report?
Yes
Is this a Product Problem Report?
No
Operator of Device
Health Professional
Device Expiration Date
06/12/2024
Device Model Number
K1054.3816
Device Catalogue Number
K1054.3816
Device Lot Number
0000089892
Was Device Available for Evaluation?
Yes
Is the Reporter a Health Professional?
Yes
Type of Report(Section G)
Thirty-Day
Initial Date Received by Manufacturer
Not provided
Initial Report FDA Received Date
04/23/2026
Was Device Evaluated by Manufacturer? (Y/N)
Yes
Date Device Manufactured
06/13/2019
Is the Device Labeled for Single Use? (Y/N)
Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device
Initial
Patient Sequence Number
1
Outcome Attributed to Adverse Event
Required Intervention;
Patient Sex
Unknown
-
-