W. L. GORE & ASSOCIATES, INC. GORE® EXCLUDER® ILIAC BRANCH ENDOPROSTHESIS; SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT Back to Search Results
Catalog Number HGB161007A
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Obstruction/Occlusion (2422); Thrombosis/Thrombus (4440)
Date of Event 08/04/2025
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
A1: no patient specific details have been provided.Therefore, the patient initials reflect the w.L.Gore internal case number.H6: a review of the manufacturing records for the device verified that the lot met all pre-release specifications.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Event or Problem Description
The following was reported to gore on august 18, 2025, from the medidata study database and imaging email: on (b)(6) 2025, this 68-year-old male patient underwent endovascular treatment for an aortoiliac aneurysm.The patient was treated with gore® devices including a gore® excluder® iliac branch endoprosthesis iliac branch component (ibc) in the left common iliac artery and gore® excluder® iliac branch endoprosthesis internal iliac component (iic) in the left internal iliac artery.A gore® viabahn® endoprosthesis with heparin bioactive surface was also implanted.The sites were accessed percutaneously on the left and right.The gore® devices were successfully navigated to the intended locations and successfully deployed.Device catheters were successfully removed after successful access, delivery and deployment of the devices.There were no access-related complications.The patient also had embolization with coils of the internal iliac artery and lumbar artery vessel(s) during the index procedure.The patient was home on (b)(6) 2025.On (b)(6) 2025, the patient had a cta that showed a mild thrombus within the ibc and iic.There was no loss of patency of the gore® devices noted.On (b)(6) 2026, the patient had a cta that showed loss of patency of excluder iliac branch endoprosthesis iliac branch component (ibc).Excluder iliac branch endoprosthesis internal iliac component (iic); viabahn endoprosthesis.No additional information was available.(*viabahn event is captured in (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® EXCLUDER® ILIAC BRANCH ENDOPROSTHESIS
Common Device Name
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
MEDICAL SILICON VALLEY B/P
2890 de la cruz blvd.
santa clara CA 95050
Manufacturer Contact
asami aizawa
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key24976855
Report Number3013164176-2026-02997
Device Sequence Number18764694
Product Code MIH
UDI-Device Identifier00733132635313
UDI-Public(01)00733132635313(17)271202
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
P020004
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2025
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Study
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 04/24/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberHGB161007A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/06/2026
Initial Report FDA Received Date04/24/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured12/03/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age68 YR
Patient SexMale
Patient Weight61 KG
-
-