Model Number 10007
Medical Device Problem Codes Failure to Recalibrate (1517); High Readings (2459)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/28/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Reportable malfunction with inomax dsir plus (b)(6) was documented and investigated under (b)(4).A review of the device's service log revealed that a delivery stopped alarm occurred as the monitored nitric oxide (no) value (i.E., actual value: 111 ppm) was greater than the absolute max of 100 ppm for 12 consecutive seconds.Afterwards, a service log entry for a failed low no cell calibration due to the low points being greater than the maximum value (max: 655 counts; actual value: 1011 counts) was observed.Although identified in the service log, the regional service center (rsc) did not experience a delivery stopped alarm during testing.The root cause for this occurrence was likely due to a malfunctioning no sensor.As a result, the device's no sensor was replaced.Trends were reviewed for this reportable condition and determined to be within the established control limits.No further action is required at this time.A full functional test was performed and the device operated according to specifications.As a result, the device was placed back into circulation for customer use.
 
Event or Problem Description
During a routine service log review for a device located in the united states, an internal employee discovered that a delivery stopped alarm had occurred due to a nitric oxide (no) concentration greater than 100 ppm followed by a failed low no sensor calibration.This service log finding meets the criteria of a reportable malfunction.There was no delivery stopped alarm complaint or report of patient harm associated with this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INOMAX DSIR PLUS (DELIVERY SYSTEM)
Common Device Name
NITRIC OXIDE ADMINISTRATION APPARATUS
Manufacturer (Section D)
MALLINCKRODT MANUFACTURING LLC
6603 femrite drive
madison WI
Manufacturer (Section G)
MALLINCKRODT MANUFACTURING LLC
6603 femrite drive
madison WI
Manufacturer Contact
mark wendelken
440 us route 22 east
suite 302
bridgewater, NJ 
MDR Report Key25055595
Report Number3004531588-2026-00019
Device Sequence Number10101517
Product Code MRN
UDI-Device Identifier00867538000106
UDI-Public(01)00867538000106
Combination Product (Y/N)N
Initial Reporter StateNJ
Initial Reporter CountryUS
PMA/510(K) Number
K061901
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 05/01/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number10007
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/16/2026
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/20/2026
Initial Report FDA Received Date05/01/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/28/2009
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-