| Model Number |
NA-U401SX-4022 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Pneumothorax (2012)
|
| Date of Event |
02/21/2026
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The investigation is ongoing.A supplemental report will be submitted when the investigation is completed or if additional information becomes available.
|
| |
|
Event or Problem Description
|
|
Olympus reviewed the literature titled ¿the vanishing lesion: a procedural clue to pneumothorax during endobronchial ultrasound¿.Literature summary endobronchial ultrasound (ebus) has become an essential tool in lung cancer staging and the diagnosis of centrally located pulmonary lesions.Vigilance during ebus-guided biopsy is crucial.The disappearance of a previously visualised lesion should raise suspicion of a developing pneumothorax.The literature highlights the experience with an intra-procedural pneumothorax following ebus-guided biopsy and discuss the procedural considerations relevant to its prompt recognition and management.Methods this is a single-patient case report describing a 52-year-old woman undergoing endobronchial ultrasound (ebus)¿guided procedures for evaluation of a right upper paratracheal lung lesion.The procedure included ebus-guided transbronchial needle aspiration (ebus-tbna) followed by an attempted ebus-guided cryobiopsy.An electrocautery knife was used to create a tract for cryoprobe insertion.Radial ebus and fluoroscopic guidance were later used for transbronchial lung cryobiopsy, with post-procedure imaging to assess complications.Results: after initial visualization of the lesion on ebus, the lesion suddenly disappeared upon reinsertion of the scope.Subsequent radial ebus-guided cryobiopsy successfully obtained tissue, confirming lung adenocarcinoma with egfr exon 19 deletion.Post-procedure chest radiography revealed a right-sided pneumothorax with subcutaneous emphysema, requiring urgent chest tube insertion.The patient recovered fully and was discharged after lung re-expansion.Retrospective review suggested the pneumothorax likely occurred intra-procedurally, most plausibly related to use of the electrocautery knife.Conclusion: the authors conclude that the sudden disappearance of a lesion during ebus should immediately raise suspicion for pneumothorax, even in the absence of obvious ventilatory or hemodynamic changes.Type of adverse events/number of patients: right-sided pneumothorax and subcutaneous emphysema in a 52 years old, female patient.There was no allegation of device malfunction identified in the article.This report is 1 of 2.
|
| |
|
Event or Problem Description
|
|
No additional information received from the customer.
|
| |
|
Additional Manufacturer Narrative
|
|
This supplemental report is being submitted to provide the legal manufacturer's investigation.The device has not been returned to olympus for evaluation.Based on the results of the investigation, the relationship between the device and the adverse event cannot be confirmed.There is no evidence of an olympus device malfunction.Therefore, the root cause cannot be determined.Should additional relevant information become available, a supplemental report will be submitted.Olympus will continue to monitor field performance for this device.
|
| |
|
Search Alerts/Recalls
|